61
ProBee-ZE10 User Guide Rev.1.1
on the implementation of this functionality by setting specific address. If set to default
value, “FFFFFFFFFFFFFFFF”, the node allows that any node can control the GPIO
status.
Execute
AT+SOURCELA?<CR>
AT+SOURCELA=<value><CR>
Response
<value><CR>
OK<CR>
OK<CR> or ERROR<CR>
Default
FFFFFFFFFFFFFFFF
Range
0000000000000000 – FFFFFFFFFFFFFFFF
7.11
Firmware Upload and Help
7.11.1 AT+BOOTLOAD or AT+BL
Description
Start bootloader to upload firmware. (blank: local, 1: passthru, 2: clone)
The device leaves the AT command line and enters the bootloader menu for uploading
new ProBee firmware. There’s no restrict to use local upload but a sleepy end device
cannot upload to remote node over the air. The current UART should be set
115200bps, 8 data bits, no parity, 1 stop bit and none flow control.
Execute
AT+BOOTLOAD<CR>
AT+BOOTLOAD=<number>,<IEEE><CR>
Response
Bootloader menu
…
Serial upload complete
Please start .ebl upload image ...<CR> or
Start cloning ...<CR>
Bootloader menu
…
Bootload Complete!
7.11.2 AT+HELP or AT+HP
Description
Show all the available commands
Execute
AT+HELP<CR>
Response
Available AT Commands
…
OK<CR>