46
ProBee-ZE10 User Guide Rev.1.1
6.4.3
End-device C onfiguration
Hardware configuration for the end device is as follows:
Set the ADC_2 and ADC_3 switch to TEMP_SENS and LIGHT_SENS
The AT commands for coordinator configuration is as follows:
AT+NODETYPE=4
OK
AT+PANID=7772
OK
ATS42=1
OK
AT+DESTLA=0001950000000001
OK
AT+GPIO=1111144111111
OK
ATZ
OK
6.4.4
Monitoring the Sensors
Once the configurations are done and the system is running, the terminal (computer) connected to the
coordinator will print out the incoming data as follows:
++0001950000000002|10000**000000|****,****,233E,006A
++0001950000000003|10000**000000|****,****,2254,0B23
++0001950000000002|10000**000000|****,****,2235,004E
++0001950000000003|10000**000000|****,****,226C,0B8B
6.5
Configuration Example #2: 1 Coordinator and 2 End-Devices
Here is another example assuming different system configurations. This example can be described as
follows:
One ZE10 module acts as a coordinator and it is connected to a host computer via serial cable.
Two ZE10 modules act as end devices.
Turn on/off the LEDs of the end devices remotely through the coordinator