60
C.23. S48: Low Power Max Interval (default 5000)
This is the max interval value to use low power mode, which is set to 5000 initially. (5000 x 625μsec =
3125msec)
C.24. S49: Low Power Min Interval (default 4500)
This is the min interval value to use low power mode, which is set to 4500 initially. (4500 x 625μsec =
2812msec)
A small interval increases power consumption, a large interval increases latency.
C.25. S52: Low Power Timeout (default 5)
This is the low power timeout value, which is set to 5 initially. (5sec)
During no data transmission in the timeout, Parani-BCDx10 will be in low power mode to save the
power. Therefore, it takes a few seconds to wake the Parani-BCDx10 out of low power mode.
C.26. S54: BD Address of Last Connected Device
This saves the Task2 BD address of the Bluetooth device connected most recently in a multiple
connection mode.
C.27. TS55: BD Address of Last Connected Device
This saves the Task3 BD address of the Bluetooth device connected most recently in a multiple
connection mode.
C.28. S56: BD Address of Last Connected Device
This saves the Task4 BD address of the Bluetooth device connected most recently in a multiple
connection mode.
C.29. S57: Slave Disconnect Timeout (default 3)
This S57 register value defines the time period in seconds that a master unit waits in case a slave unit
does not receive the data sent from the master. For this time period, the master unit will not send data
to all slave units if any slave unit does not receive the data. If the slave unit does not receive the data
after this time period elapses, the master unit will disconnect the connection with the problematic slave
unit. The value should be greater than 0 and smaller than the Supervision Timeout(S37).
C.30. S58: MAX TX POWER (default 0)
This value describes the peak output power. Setting this causes rebooting and applying. (There is a
little deviation according to the devices.)
BCD110
Parameter
dBm
0
Use chip setting.
1
-14
2
-10
3
-5
4
0
5
5
Содержание Parani-BCD110
Страница 1: ...Parani BCD110 210 User Guide Version 2 0 6 2 2012 06 28 ...
Страница 17: ...17 Figure 3 2 Main Window Figure 3 3 Information Window ...
Страница 37: ...37 Appendix A Connections A 1 Pin Assignment A 1 1 Parani BCD110 ...
Страница 39: ...39 A 1 2 Parani BCD210 ...
Страница 65: ...65 Appendix F How to make a RS232 interface Development Board BCD110 Module Interface BCD210 Module Interface ...
Страница 66: ...66 Power and Reset Interface RS232 Serial Interface ...
Страница 67: ...67 Switch Interface LED Interface ...
Страница 68: ...68 Appendix G Parani BCD110 PCB mechanical drawing BCD110SU BCD110DU BCD110SC BCD110DC ...
Страница 69: ...69 BCD110DS SMD Type DIP Type ...
Страница 70: ...70 Appendix H Parani BCD210 PCB mechanical drawing BCD210SU BCD210DU BCD210SC BCD210DC ...
Страница 71: ...71 BCD210DS BCD210SU SC BCD210DU DC DS ...