54
GB
commeo initial operation/Setting by radio
Note for settings under point 5.2.:
The motor must be selected for this setting with
a transmitter in
SELECT
mode (Status LED flashes slowly in orange). After completing
the setting, the motor is still selected (see point 5.).
5.2.2. Manual setup-mode, deletion and manual setting of the end positions
¨
in operation bottom position, top stop/release
When the movement is interrupted once, the system is in manual setup-mode.
Important:
A limit stop for the upper end limit is necessary!
First the lower end limit has to be run-up to. From there move against the upper limit
stop
without
interruption.
Operation
Drive
6 s
Press the
STOP
button of the transmitter for 6 seconds.
The motor will switch to manual setting mode. Both limit
positions already set will be deleted.
or
Move the motor to the
lower
end position with the
UP
or
DOWN
button.
3 s
Press the
STOP
button of the transmitter for 3 seconds.
The correct rotation direction assignment will be carried out
at the end of the end position setting.
or
Run against the limit stop
at the top without stopping;
the
motor
stops automatically.
The correct direction of rotation
assignment has been made.
Perform a test run: The drive moves up against the limit stop
and
relieves shortly.
Note:
The transmitter may not yet have been programmed.
See point 5.2.4. to program a transmitter.