Setting of the end positions with setting switch
4.5.1. Semi-automatic setup-mode, deletion and semi-automatic setting of the
end positions
¨
in operation bottom position, top stop/release
When the movement is interrupted twice during operation, the system is in semi-
automatic setup-mode. The drive will only find the upper end limit automatically.
Important:
A limit stop for the upper end limit is necessary!
First the lower end limit has to be run-up to. From there move against the upper limit
stop
without
interruption, until the motor is automatically switched off.
Setting with
switch
Setting with
setting switch
Drive
E
1 s
Press the
E
button of the setting switch for
1 second. Both limit positions already set will be
deleted.
Note:
Not required for the initial installation or after
resetting to factory defaults.
or
E
Move the motor with the
UP
or
DOWN
button
downwards
to the requested lower end limit.
Run against the limit stop
at the top without stop-
ping;
the motor
stops automatically.
The correct
direction of rotation assignment has been made.
Perform a test run: The drive moves up against the
limit stop and
relieves shortly.