background image

Selmo

 

Comfort technology division

“THESIS DUAL”

 

Electronic control for towel radiator 

Rev.  05 July 2015

Selmo 

Electronic

 

Via Pacinotti, 24 - 35030 Rubano 

(PD) Italy- Tel +39.049.8976761, Fax +39.049.8976085 - 

www.selmo.it

 

EN

 

 

 

 

 

Technical Characteristics

 

Product

 

Digital electronic thermostat for towel radiators

 

Applications

 

Towel radiators

 

Insulation class

 

Class 

I

,  Class 

II

 

IP level

 

IP44

 

Fil-Pilote

 

Available for Class 

II 

models

 

 

Temperature setting

 

Digital (buttons [ + ] and [ - ])

 

Indication lights  

 

- Backlit On/Off button.

 

- Led indicating the selected functional mode.

 

- Led display.

 

-Comfort, Night, Antifreeze, Stand-by, Fil-Pilote, 
Timer-2h.

 

Operational modes

 

 
Selectable temperature range of the 
towel radiator in Comfort mode

 

 
30°C  -  70°C

 

Selectable temperature range of the 
room in Comfort mode 

 

10°C  -  32°C

 

Operating temperature

 

-10°C  -  +40°C

 

Maximal power

 

2000W

 

Supply voltage

 

230Vac 50Hz

 

Size

 

113 x 73 x 40mm (H x W x D)

 

Connections

 

Faston connector 4.8x0.5mm for the Earth 
connection, 4 poles connector for the heating 
element with temperature sensor (Live, Neutral, 
internal sensor, external sensor).

 

Internal and external sensor

 

10K



a 25°C, NTC type

 

Warranty

 

2 years

 

Compliant standards

 

EN 60335-2-43, EN 55014-1, EN 61000-3-2,

 

EN 61000-3-3, EN 55014-2, EN 50366

 

EN 60335-1, EN 60335-2-30.

 

Certification mark

 

CE

 

Environmental directives

 

WEEE,  RoHS

 

Electromagnetic compatibility

 

89/336/EEC

 

Содержание Thesis Digital

Страница 1: ...to install and it is available in different colors THESIS Dual is a certified product THESISDualis compliant with the following standards Eco design Directive for Energy using Products 2005 32 EC 0 5W...

Страница 2: ...ifreeze Stand by Fil Pilote Timer 2h Operational modes Selectable temperature range of the towel radiator in Comfort mode 30 C 70 C Selectable temperature range of the room in Comfort mode 10 C 32 C O...

Страница 3: ...supply before cleaning or performing maintenance of the product In case of damage of the power supply cable shut down the device and do not tamper with it The damaged power supply cables can be repla...

Страница 4: ...power of the towel radiator Thesis dual is compatible with the type of heating elements shown in the following picture Earth connection Only Class I Female 4 poles connector to Thesis Dual Heating ele...

Страница 5: ...irectives 9 The device has to be protected by a 30mA circuit breaker RCD 10 Power the device with the recommended voltage see technical specifications 11 If a device is directly connected to a fixed e...

Страница 6: ...the Fil Pilote system can remotely control a Thesis Dual device with Fil Pilote functionality Class II The brown wire is the Live wire L the gray wire is the Neutral wire N and the black wire is used...

Страница 7: ...stat regulation based on room temperature The selection between these two operative modes is done through the Select 5 button When the Room thermostat mode is active the led indicator 3 is turned on W...

Страница 8: ...ed above Night Icon moon 10 it is similar to the Comfort function but the temperature range is between 9 C and 31 C in Room thermostat mode and between 29 C and 69 C in Towel radiator mode Antifreeze...

Страница 9: ...ve 2 Comfort maintains the Comfort temperature set by the user 3 ECO maintains the room temperature 3 5 C below the Comfort temperature 4 Anti freeze maintains the room temperature at 7 C 5 Eco 1 main...

Отзывы: