Posizionatore angolare APX 700 - Manuale d'uso - 37
••
Configuration
APX 700 has several configuration options that allow to set:
- Keyboard access code
- Outputs (cams) number (and automatically the number of modes)
- Speed limit
- Direction of positive rotation of the encoder
- Relative zero position of the encoder
- Mode selection type
- Error recovering mode
- Encoder type (PNP or NPN)
- Advance/delay notation (degree or milliseconds)
- Automatic linear advance for all 16 cams (4 advances, one for each 4-cams)
- Language (5 languages available)
The factory settings are:
- No keyboard code set
- 16 outputs (cams) and 8 programming modes (cycles)
- Speed limit = 9999 RPM (practically disabled)
- Positive rotation clockwise
- Relative zero = Absolute zero
- Manual mode selection (in programming)
- Automatic error recovering
- PNP encoder
- Advance/ delay notation = degree
- No advance set
- English language
In the rest of the chapter we will describe each configuration option.
Modalità
Tasto Effetto
Configurazione
FN + 0
Change keyboard access code
FN + 1
Set number of outputs
FN + 2
Encoder setup: type (PNP / NPN), positive
direction, speed limit
FN + 3
Set language
FN + 4
Automatic or manual encoder reset
FN + 5
Set mode selection type
FN + 6
Set error recovering mode
FN + 7
Set advance/delay notation (degree / ms)
FN + 8
Set linear advance
FN + 9
Display current configuration
ESC
Switch to Configuration / Programming mode
Note: Pressing
ESC
key APX 700 returns in
Configuration/Programming
menu, which allows to return in
Configuration
mode (by pressing
1
), go to
Programming
mode (by pressing
2
) or to
Execution
mode (by
pressing
FN + ON
).