Posizionatore angolare APX 700 - Manuale d'uso - 34
If the type of the connected encoder is PNP, the "
P/N
" terminal (see the next figure) results connected
to the "
+
" terminal of the DB-15 connector.
In case in which is required to change externally the active mode to APX 700, you must select in the
first place through the function
FN + 5
(setting mode (cycle) selection type) the option 1 (EXTERNAL).
Then, connect the input terminals (M0÷M3) in according to the encoder type used (PNP or NPN) like
shown below:
P
/
N
M0
M1
M2
M3
DB15
We report the combinations table of the M0 ÷ M3 terminals that permitts to define the overall number
of modes:
M3 M2 M1 M0 Active mode
0 0 0 0
0
0 0 0 1
1
0 0 1 0
2
0 0 1 1
3
0 1 0 0
4
0 1 0 1
5
0 1 1 0
6
0 1 1 1
7
1 0 0 0
8
1 0 0 1
9
1 0 1 0
10
1 0 1 1
11
1 1 0 0
12
1 1 0 1
13
1 1 1 0
14
1 1 1 1
15