![Selectronic 2506.192 Скачать руководство пользователя страница 8](http://html.mh-extra.com/html/selectronic/2506-192/2506-192_installation-instructions-manual_1236904008.webp)
CAUTION
GENERAL CLEANING; Fig. 5
1.
For general cleaning use a damp, soft cloth to clean
the spout and the sensor.
2.
For cleaning dirt use a soft cloth with diluted dish
washing detergent. Wipe the area using a wet cloth
and dry using a soft cloth.
Do not scratch the sensor when cleaning.
Avoid using anything that may scratch the spout
surface.
Never use polishing power, detergent or a
nylon scrub brush. They will damage the surface of the
spout or Sensor.
1.
Remove ENCLOSURE COVER.
2.
Close SUPPLY STOP
(5)
with 4mm Hex wrench.
Note: Keep water flowing out of faucet while shutting off.
3.
Pull off Red (1) and Black
(2)
CONNECTORS from
SOLENOID VALVE
(3)
.
4.
Unthread STRAINER
(4)
using a 7/16" socket.
5.
Pull out the STRAINER
(4)
and clean with an old
toothbrush. Rinse thoroughly with water.
6.
Install the STRAINER
(4)
back in its place and
tighten with a 7/16" socket.
Caution: do not over tighten strainer.
Note: It is recommended to clean strainer every 6
months.
7.
Replace ENCLOSURE COVER. Tighten cover
screws firmly.