Selectronic 2506.192 Скачать руководство пользователя страница 5

Fig. 1e

8

10

ELECTRICAL INSTALLATION

M 9 6 5 2 74

4

Fig. 1

Fig. 1b

1.

 Remove ENCLOSURE COVER 

(1)

Fig. 1.

 

2. 

Feed the WIRE CONNECTORS 

(2)

 through the top 

of ENCLOSURE 

(5)

Fig. 1a.

3.

 Remove GROMMET 

(4)

 from ENCLOSURE 

(5)

Fig. 1.

4.

 Feed the gray SENSOR WIRE 

(7)

  through 

GROMMET 

(4)

, 4" from CONNECTOR. 

Fig. 1b.

 Insert 

gray SENSOR WIRE 

(7)

 into SPLIT PLUG 

(9)

. Push 

SPLIT PLUG 

(9)

 into GROMMET 

(4)

 to seal. 

Fig. 1d.

5.

 Insert GROMMET 

(4)

 back into ENCLOSURE 

(5)

Fig. 1c.

6.

 Install CIRCUIT BOARD 

(3)

 into ENCLOSURE 

(5)

 

with SENSOR WIRE 

(7)

 under BOARD. 

Fig. 1c.

7.

 Insert SENSOR WIRE CONNECTOR 

(8) 

and 

EXTENSION WIRE CONNECTOR

 (11)

 into available 

CIRCUIT BOARD RECEPTORS 

(10)

 slots. 

Fig. 1e.

  

8.

 Connect wires from SENSOR to SOLENOID VALVE 

(6)

 (Red to +, Black to -). 

Fig. 1d.

9. 

Replace ENCLOSURE COVER 

(1)

. Tighten cover 

screws firmly. 

10.

 

Contractor to supply ELECTRICAL BOX (12) 

and connection to ENCLOSURE (5). 

Mount POWER 

SUPPLY 

(13)

 into ELECTRICAL BOX 

(12)

.  Connect 

White and Black power connections to POWER 
SUPPLY CABLE 

(14)

.

 Fig. 1f.

11.

 Connect the EXTENSION WIRE 

(16)

 to the 

POWER SUPPLY CABLE 

(15)

FIG. 1f.

    ELECTRICAL CONNECTIONS; Fig. 1

1

4

8

RED

6

Fig. 1c

Fig. 1d

7

4

9

1

4

7

5

4

4"

3

CAUTION

Before opening ENCLOSURE

disconnect AC power supply.

BLACK

F

5

2

Fig. 1a

5

7

10
11

Fig. 1f

BLACK & WHITE

POWER

CONNECTIONS

15

13

CONNECTOR NOT

USED IN THIS 

INSTALLATION

16

14

4" ELECTRICAL BOX

OR EQUIVALENT BY

OTHERS

12

Содержание 2506.192

Страница 1: ...ER Please give this manual to the customer after installation In Toronto Area only 1 905 3061093 I n s t a l l a t i o n I n s t ru c t i o n s I n s t a l l a t i o n I n s t ru c t i o n s 2007 American Standard Certified to comply with ASME A112 18 1M M965274 2506 192 2506 195 SELECTRONIC Hard Wired AC Powered Moments Lavatory Proximity Faucet PRODUCT NUMBERS Product No s Options Specifications...

Страница 2: ...MBER 2506 192 with cast spout 1 5 GPM vandal resistant aerator 2506 195 with cast spout 0 5 GPM vandal resistant aerator OPTIONAL Mixing Valve 605XTMV Thermostatic mixing valve flex hoses 3 8 compression 20 hose length M965274 DO NOT REMOVE PROTECTIVE FILM FROM SENSOR EYE UNTIL INSTALLATION IS COMPLETE 6 5 In Toronto Area only 1 905 3061093 To learn more about American Standard Faucets visit our w...

Страница 3: ... checks and flexible stainless steel 15 reach inlet hose for spout connection 159mm 6 1 4 126mm 5 154mm 6 1 16 FINISHED WALL Fig 1a Fig 1b 1 4 6 5 3 2 INSTALL SPOUT ASSEMBLY Fig 1 CAUTION Turn off hot and cold water supplies before beginning 1 1 Insert WIRES 1 FLEX HOSE 2 and SPOUT SHANK 3 through center hole of mounting surface Fig 1a 2 Assemble C WASHER 4 STAR WASHER 5 and LOCKNUT 6 onto threads...

Страница 4: ...TING HOLES SUPPLIES WASTE ENCLOSURE MOUNTING HOLES LAVATORY RIM OR MOUNTING SURFACE 3 NOTE If using Mixing Valve optional See Sheet M968808 for installation instructions MOUNT ENCLOSURE Fig 2 2 1 Connect SUPPLY NUT 1 from spout assembly to nipple on top of ENCLOSURE 2 Tighten with adjustable wrench to make a water tight connection Fig 3 NOTE If using the optional Mixing Valve See Sheet M968808 for...

Страница 5: ...NNECTOR 11 into available CIRCUIT BOARD RECEPTORS 10 slots Fig 1e 8 Connect wires from SENSOR to SOLENOID VALVE 6 Red to Black to Fig 1d 9 Replace ENCLOSURE COVER 1 Tighten cover screws firmly 10 Contractor to supply ELECTRICAL BOX 12 and connection to ENCLOSURE 5 Mount POWER SUPPLY 13 into ELECTRICAL BOX 12 Connect White and Black power connections to POWER SUPPLY CABLE 14 Fig 1f 11 Connect the E...

Страница 6: ...Unit 2 approximately 4 from connector Fig 3 Push SPLIT PLUG 7 into GROMMET 8 to seal 7 Insert connector of 10 ft EXTENSION into lower receptor as shown in fig 3 on CIRCUIT BOARD 6 of Unit 2 8 Feed gray sensor wire 9 from Unit 2 through upper U GROMMET 10 of Unit 2 ENCLOSURE 4 from connector Fig 3 Insert wire into SPLIT PLUG 7 Push SPLIT PLUG 7 into GROMMET 8 to seal Fig 3a 9 Insert GROMMET 2 back ...

Страница 7: ...TROL LED 2 is blinking slowly place your hand 1 2 in 30 50mm in front of the sensor Fig 2a 3 When the LED stops blinking and stays ON move your hand to the desired position and hold in place until the LED begins to blink again Fig 2a 4 Once the SENSOR CONTROL LED 2 begins to blink again remove your hand from the detection zone When the flashing stops the detection distance is set HOW TO CHANGE SEN...

Страница 8: ...CLOSURE COVER 2 Close SUPPLY STOP 5 with 4mm Hex wrench Note Keep water flowing out of faucet while shutting off 3 Pull off Red 1 and Black 2 CONNECTORS from SOLENOID VALVE 3 4 Unthread STRAINER 4 using a 7 16 socket 5 Pull out the STRAINER 4 and clean with an old toothbrush Rinse thoroughly with water 6 Install the STRAINER 4 back in its place and tighten with a 7 16 socket Caution do not over ti...

Страница 9: ...ow out of faucet when I m in the sensor range A Check sensor If sensor blinks 2 times interrupted by pause replace battery or call 1800 442 1902 Q Why does the faucet operate the opposite of expected Turns On when not in sensor range but turns off when in sensor range A Sensor wires to solenoid are reversed Black to Red to is correct Q What is the normal operating pressure range A Faucet will oper...

Отзывы: