Selectronic 2506.192 Скачать руководство пользователя страница 4

Fig. 2

1.

 Determine location of ENCLOSURE 

(1)

. It must be 

located with-in the 14" (356mm) by 21" (533mm) 
shaded area shown in 

Figure 2

 in order for electrical 

connections from the spout assembly to be made.

NOTE: ENCLOSURE SUPPLY HOSE is 20". Distance 
between wall supply and ENCLOSURE (1) must be 
taken into consideration.

2.

 Remove 4 screws from COVER 

(2)

 and pull off 

COVER 

(2)

. Hold the ENCLOSURE 

(1)

 in desired 

location and mark the four mounting hole locations as 
shown. 

Fig. 2.

3.

 The ENCLOSURE 

(1)

 works best if secured to a wall 

stud or cross brace within the wall, using the SCREWS 

(3)

 supplied. If the ENCLOSURE 

(1)

 is to be installed on 

a tile or plaster wall the ANCHORS 

(4)

 and SCREWS 

(3)

 should be used.

4. 

For installations on drywall or tiled walls;

 use 

ANCHORS 

(4)

 and SCREWS 

(3)

 for securing 

ENCLOSURE 

(1)

 to finished wall. Drill four 1/4" dia. 

holes a minimum of 1-3/4" deep. Insert the four 
ANCHORS 

(4)

 flush with face of the finished wall.

Align the ENCLOSURE 

(1)

 and Install the MOUNTING 

SCREWS 

(3)

. Tighten to secure ENCLOSURE 

(1)

 to 

mounting surface.
  

14"

(356mm)

3-3/4"

(96mm)

2-3/4"

(71mm)

3"

(76mm)

21"

(mm)

2

4

3

1

1

1

20"

(500mm)

MOUNTING HOLES

SUPPLIES

WASTE

ENCLOSURE

MOUNTING

HOLES

LAVATORY RIM OR

MOUNTING SURFACE

3

NOTE: If using Mixing Valve (optional) See Sheet 
#M968808 for installation instructions.

    MOUNT ENCLOSURE; Fig. 2

2

1. 

 Connect SUPPLY NUT 

(1)

  from spout assembly to 

nipple on top of ENCLOSURE 

(2)

. Tighten with 

adjustable wrench to make a water tight connection. 

Fig. 3.

NOTE; If using the optional Mixing Valve See Sheet 
#M968808 for installation instructions.

    CONNECT SPOUT HOSE TO

ENCLOSURE; Fig. 3

    CONNECT WATER SUPPLY TO 

ENCLOSURE AND WALL SUPPLY;

Fig. 4

3

Fig. 3

4

1

2

1

3

3

Fig. 4

2

1. 

Insert FIBER WASHER 

(4)

 into SUPPLY NUT 

(1)

 on 

ENCLOSURE 

(2)

.

2. 

Connect SUPPLY NUT

 (1)

 on ENCLOSURE

 (2)

 to 

FLEXIBLE SUPPLY HOSE 

(3)

. Tighten to make a 

water tight connection. Use two wrenches to tighten if 
necessary. 

Fig. 4.

3.

 Connect FLEXIBLE SUPPLY 

(3)

 directly to wall supply. 

Connection on FLEXIBLE SUPPLY 

(3)

 is 3/8" 

compression. Use adjustable wrench to tighten 

connection. Do not over tighten. 

Fig. 4a.

Note: 

FLEXIBLE SUPPLY 

(3)

 measures 20" from the 

bottom of the ENCLOSURE 

(1)

 base. If additional 

supply length is required, installer must purchase parts 

separately.

Important: 

If FLEXIBLE SUPPLY 

(3)

 is too long, loop to 

avoid kinking.

COLD WATER OR

TEMPERED

WALL SUPPLY

4

Fig. 4a

DO NOT USE PIPE

SEALANT ON THREADS

M 9 6 5 2 74

4" ELECTRICAL BOX

OR EQUIVALENT BY

OTHERS

Содержание 2506.192

Страница 1: ...ER Please give this manual to the customer after installation In Toronto Area only 1 905 3061093 I n s t a l l a t i o n I n s t ru c t i o n s I n s t a l l a t i o n I n s t ru c t i o n s 2007 American Standard Certified to comply with ASME A112 18 1M M965274 2506 192 2506 195 SELECTRONIC Hard Wired AC Powered Moments Lavatory Proximity Faucet PRODUCT NUMBERS Product No s Options Specifications...

Страница 2: ...MBER 2506 192 with cast spout 1 5 GPM vandal resistant aerator 2506 195 with cast spout 0 5 GPM vandal resistant aerator OPTIONAL Mixing Valve 605XTMV Thermostatic mixing valve flex hoses 3 8 compression 20 hose length M965274 DO NOT REMOVE PROTECTIVE FILM FROM SENSOR EYE UNTIL INSTALLATION IS COMPLETE 6 5 In Toronto Area only 1 905 3061093 To learn more about American Standard Faucets visit our w...

Страница 3: ... checks and flexible stainless steel 15 reach inlet hose for spout connection 159mm 6 1 4 126mm 5 154mm 6 1 16 FINISHED WALL Fig 1a Fig 1b 1 4 6 5 3 2 INSTALL SPOUT ASSEMBLY Fig 1 CAUTION Turn off hot and cold water supplies before beginning 1 1 Insert WIRES 1 FLEX HOSE 2 and SPOUT SHANK 3 through center hole of mounting surface Fig 1a 2 Assemble C WASHER 4 STAR WASHER 5 and LOCKNUT 6 onto threads...

Страница 4: ...TING HOLES SUPPLIES WASTE ENCLOSURE MOUNTING HOLES LAVATORY RIM OR MOUNTING SURFACE 3 NOTE If using Mixing Valve optional See Sheet M968808 for installation instructions MOUNT ENCLOSURE Fig 2 2 1 Connect SUPPLY NUT 1 from spout assembly to nipple on top of ENCLOSURE 2 Tighten with adjustable wrench to make a water tight connection Fig 3 NOTE If using the optional Mixing Valve See Sheet M968808 for...

Страница 5: ...NNECTOR 11 into available CIRCUIT BOARD RECEPTORS 10 slots Fig 1e 8 Connect wires from SENSOR to SOLENOID VALVE 6 Red to Black to Fig 1d 9 Replace ENCLOSURE COVER 1 Tighten cover screws firmly 10 Contractor to supply ELECTRICAL BOX 12 and connection to ENCLOSURE 5 Mount POWER SUPPLY 13 into ELECTRICAL BOX 12 Connect White and Black power connections to POWER SUPPLY CABLE 14 Fig 1f 11 Connect the E...

Страница 6: ...Unit 2 approximately 4 from connector Fig 3 Push SPLIT PLUG 7 into GROMMET 8 to seal 7 Insert connector of 10 ft EXTENSION into lower receptor as shown in fig 3 on CIRCUIT BOARD 6 of Unit 2 8 Feed gray sensor wire 9 from Unit 2 through upper U GROMMET 10 of Unit 2 ENCLOSURE 4 from connector Fig 3 Insert wire into SPLIT PLUG 7 Push SPLIT PLUG 7 into GROMMET 8 to seal Fig 3a 9 Insert GROMMET 2 back ...

Страница 7: ...TROL LED 2 is blinking slowly place your hand 1 2 in 30 50mm in front of the sensor Fig 2a 3 When the LED stops blinking and stays ON move your hand to the desired position and hold in place until the LED begins to blink again Fig 2a 4 Once the SENSOR CONTROL LED 2 begins to blink again remove your hand from the detection zone When the flashing stops the detection distance is set HOW TO CHANGE SEN...

Страница 8: ...CLOSURE COVER 2 Close SUPPLY STOP 5 with 4mm Hex wrench Note Keep water flowing out of faucet while shutting off 3 Pull off Red 1 and Black 2 CONNECTORS from SOLENOID VALVE 3 4 Unthread STRAINER 4 using a 7 16 socket 5 Pull out the STRAINER 4 and clean with an old toothbrush Rinse thoroughly with water 6 Install the STRAINER 4 back in its place and tighten with a 7 16 socket Caution do not over ti...

Страница 9: ...ow out of faucet when I m in the sensor range A Check sensor If sensor blinks 2 times interrupted by pause replace battery or call 1800 442 1902 Q Why does the faucet operate the opposite of expected Turns On when not in sensor range but turns off when in sensor range A Sensor wires to solenoid are reversed Black to Red to is correct Q What is the normal operating pressure range A Faucet will oper...

Отзывы: