OPTIONAL PARTS LIST

PACKAGE CONTENTS

Twin Head Assembled #:

 300-778HD

Pressure Gauge #: 

300-023FA

Plastic 3/4” Shut-Off Valve #:

 300-743

Inlet Fitting 3/4” #: 

300-714

Outlet Fitting 3/4” #:

 300-720

Pressure Relief Valve #:

 300-738

3/4” Plug #: 

300-715

Blue Retaining Clip #:

 300-708E

Plastic Housing (Comes Assembled)

1 Filtration Cartridges

Spare Parts Kit (1 Lubricant Pack, 2 Clips, 2 O-Rings, 1 

Inlet, 1 Outlet)

Instructions/Assembly Use and Care Manual

GENERAL NOTES

WARNING

It is important to ensure that you are in compliance with all applicable state and 

local plumbing codes before you start installation of this product. Use of a licensed 

technician for installation is recommended. All steps provided throughout are for 

the typical installation only.

1) 

Read and understand all of the instructions before attempting to install and operate this equipment.  

 

Failure to do so may result in injury and damage to person and/or property.

2)  

Prior to installation, shut off the water.

3)

  It is important to ensure the mounting to the wall is strong enough to bear the water weight

 

of the product.

 

4)

  Do NOT install system direct to the sunlight or freezing environment.

5)  

When working with hard copper piping, keep all heat sources at least 18” away from plastic  

 

 

components. The plastic components can be damaged by heat from the torch which may be used in  

 

the installation.

6)  

After installation, check all connections for leaks before operating the unit.

7) 

Refer to the Installation Procedures to ensure that all clips are in the right position before

 

operating the unit.

THANK YOU FOR PURCHASING OUR PRODUCT

Everyone here at Selecto, Inc. would like to thank you for your support and 

continued use of our products. We believe everyone should have access to safe, 

clean water. Your purchase is a small step towards a clean future.

Содержание SP20-1

Страница 1: ...SUPERPLUS WATER FILTRATION SYSTEM For Model SP20 1 INSTRUCTIONS ASSEMBLY USE AND CARE MANUAL Important Read this manual thoroughly before install ...

Страница 2: ...ctions to Reverse Water Flow Cartridge Change Out Instructions QR Code Instructions Troubleshooting Repair Limited Warranty 2 3 4 6 8 9 10 11 12 HELP AND SUPPORT Selecto Inc 3980 Lakefield Court Suwanee GA 30024 USA WWW SELECTOINC COM Product Customer Support Hotline Toll Free 1 800 635 4017 Customer Service SelectoInc com Monday to Friday 8 00 a m 5 00 p m EST ...

Страница 3: ...tempting to install and operate this equipment Failure to do so may result in injury and damage to person and or property 2 Prior to installation shut off the water 3 It is important to ensure the mounting to the wall is strong enough to bear the water weight of the product 4 Do NOT install system direct to the sunlight or freezing environment 5 When working with hard copper piping keep all heat s...

Страница 4: ... capacity at 15 GPM Temperature range between 34 F and 100 F Minimum pressure 40 PSI Maximum pressure 120 PSI Dimensions 22 9 14 5 Weight With Water 27 lbs Without Water 14 lbs Replacement Filtration Cartridge SP20 1RC ABOUT YOUR PRODUCT ...

Страница 5: ...and mount the filter head 3 Pull and separate inlet Shut Off valve fitting 2 Remove blue clip from inlet side 4 Connect inlet fitting onto 3 4 hard piping B You can slide the heads out toward either side of channel to separate backplate for easy installation 5 Reconnect plastic fitting back to the filter head Tap Water Inlet Filtered Water Outlet ...

Страница 6: ...e Installing steps 6 to 10 of 10 6 Re install retaining blue clip 8 Repeat steps 2 7 for the outlet side of piping 9 Install cartridge w align 7 Hand press down the clip and flush w head surface 10 Now the installation is complete Tap Water Inlet Filtered Water Outlet ...

Страница 7: ...TER HEAD 4 Connect inlet fitting onto 3 4 hard piping 2 Remove blue clip from inlet side 5 Reconnect plastic fitting back to the filter head 3 Pull and separate inlet Shut Off valve fitting A Filter Head Assembly B You can slide the heads out toward either side of channel to separate backplate for easy installation Tap Water Inlet Filtered Water Outlet ...

Страница 8: ...let side of piping 9 Apply sealant on 3 4 CPVC pipe 10 Reconnect plastic fitting clip back to the filter head 11 Installed Plastic pipe 12 Install 1st cartridge w align 4 tags 13 Now the installation is complete Tap Water Inlet Filtered Water Outlet 6 Re install retaining blue clip 7 Hand press down the clip and flush w head surface ...

Страница 9: ... install all fittings back on the filter head If using hard copper piping use the same technique from pages 4 and 5 ref Steps 2 7 If using rigid plastic piping use the same technique from pages 6 and 7 ref Steps 2 7 Plug 300 715 Plug 300 715 Filtered Outlet 300 720 Filtered Outlet 300 720 Tap Inlet 300 714 Tap Inlet 300 714 Reversal of water flow path from right to left completed How to reverse th...

Страница 10: ... Cartridges should be changed at least once a year when the pres sure on the gauge has dropped into the red zone less than 20 psi or when bad taste and or odor return 1 Shut off inlet valve 2 Push Red pressure relief button to relieve pressure 3 Grasp filter cartridge and twist 1 8 counter clockwise turn 4 Pull downward about 2 to remove the filter cartridge 5 From the new cartridge remove and dis...

Страница 11: ... Use the QR code to register and receive an email alert when it s time to change the filtration cartridges to maximize filter performance 1 Scan the QR code on filter cartridge label with your smart phone 2 Follow the instructions on the screen to either register for filter replacement reminders or to order replacement filters 3 You will receive reminders via email to change your filter cartridge ...

Страница 12: ...il the shoulder on the fitting contacts the filter head Examine the retaining clip for any cracks from removal and re insert by pushing straight down until it is all the way in If retaining clip is cracked or stretched in any way discard it and use a new one supplied If the above procedure does not cure the leak repeat the processes above replacing the O Ring supplied Leaks Between Cartridge and F...

Страница 13: ...obligations of repair replacement or refund are conditional upon return of the defective Product to SELECTO If any Product covered hereby is actually defective within the terms of this warranty then SELECTO will bear all reasonable and proper shipping or mailing charges incurred in the return of the Product as set forth herein If the Product proves not to be defective within the terms of this Warr...

Страница 14: ... concealed damage or loss is noted while unpacking the shipment the carrier should be notified immediately per I C C Regulations SELECTO must be notified in writing including a copy of the carrier s claim form of any damage or loss claims with 15 days of receipt Failure to notify SELECTO releases SELECTO from any liability How state law applies This warranty gives you specific legal rights and you...

Отзывы: