XW70LH
5/5
Kind of action:
1B;
Pollution grade:
2;
Software class:
A.;
Rated impulsive voltage
: 2500V;
Over voltage Category
: II
Operating temperature:
0÷60 °C;
Storage temperature:
-30÷85 °C.
Relative humidity:
20
85% (no condensing)
Measuring and regulation range: NTC probe:
-40÷110°C (-40÷230°F);
PTC probe:
-50÷150°C (-58÷302°F)
Resolution:
0,1 °C or 1°C or 1 °F (selectable);
Accuracy (ambient temp. 25°C)
: ±0,7 °C ±1 digit
16.
CONNECTIONS
Supply: 120Vac or 24Vac:
connect to terminals 11-12
The X-REP
output
is optional
The light relay
can be also 16(5)A according to the model
17.
DEFAULT SETTING VALUES
Label
Name
Range
°C/°F Level
Set
Set point
LS÷US
-5.0
- - -
rtc*
Real time clock menu
-
-
Pr1
Hy
Differential
0,1
25.5°C/ 1
255°F
2.0
Pr1
LS
Minimum set point
-50°C
SET/-58°F
SET
-50.0
Pr2
US
Maximum set point
SET
110°C/ SET
230°F
110
Pr2
Ot
Thermostat probe calibration
-12
12°C /-120
120°F
0.0
Pr1
P2P
Evaporator probe presence
n=not present; Y=pres.
Y
Pr1
OE
Evaporator probe calibration
-12
12°C /-120
120°F
0.0
Pr2
P3P
Third probe presence
n=not present; Y=pres.
n
Pr2
O3
Third probe calibration
-12
12°C /-120
120°F
0
Pr2
P4P
Fourth probe presence
n=not present; Y=pres.
n
Pr2
O4
Fourth probe calibration
-12
12°C /-120
120°F
0
Pr2
OdS
Outputs delay at start up
0÷255 min
0
Pr2
AC
Anti-short cycle delay
0
50 min
1
Pr1
Ac1
Second compressor start delay
0÷255s
5
Pr2
rtr
P1-P2 percentage for regulation
0 ÷ 100 (100=P1 , 0=P2)
100
Pr2
CCt
Continuous cycle duration
0.0÷24.0h
0.0
Pr2
CCS
Set point for continuous cycle
(-55.0÷150,0°C) (-67÷302°F)
-5
Pr2
COn
Compressor ON time with faulty probe
0
255 min
15
Pr2
COF
Compressor OFF time with faulty probe 0
255 min
30
Pr2
CF
Temperature measurement unit
°C
°F
°C
Pr2
rES
Resolution
in=integer; dE= dec.point
dE
Pr1
Lod
Probe displayed
P1;P2
P1
Pr2
rEd
2
X-REP display
P1 – P2 – P3 – P4 – SEt – dtr
P1
Pr2
dLy
Display temperature delay
0 ÷ 20.0 min (10 sec.)
0.0
Pr2
dtr
P1-P2 percentage for display
1 ÷ 99
50
Pr2
EdF*
Kind of interval for defrost
rtc ÷in
in
Pr2.
tdF
Defrost type
EL=el. heater; in= hot gas
EL
Pr1
dFP
Probe selection for defrost termination
nP; P1; P2; P3; P4
P2
Pr2
dtE
Defrost termination temperature
-50
50 °C
8
Pr1
IdF
Interval between defrost cycles
1
120 ore
6
Pr1
MdF
(Maximum) length for defrost
0
255 min
30
Pr1
dSd
Start defrost delay
0÷99min
0
Pr2
dFd
Displaying during defrost
rt, it, SEt, DEF
it
Pr2
dAd
MAX display delay after defrost
0 ÷ 255 min
30
Pr2
Fdt
Draining time
0÷120 min
0
Pr2
dPo
First defrost after start-up
n=after IdF; y=immed.
n
Pr2
dAF
Defrost delay after fast freezing
0 ÷ 23h e 50’
0.0
Pr2
Fnc
Fan operating mode
C-n, o-n, C-y, o-Y
o-n
Pr1
Fnd
Fan delay after defrost
0÷255min
10
Pr1
Fct
Differential of temperature for forced
activation of fans
0÷50°C
10
Pr2
FSt
Fan stop temperature
-50÷50°C/-58÷122°F
2
Pr1
Fon
Fan on time with compressor off
0÷15 (min.)
0
Pr2
FoF
Fan off time with compressor off
0÷15 (min.)
0
Pr2
FAP
Probe selection for fan management
nP; P1; P2; P3; P4
P2
Pr2
ACH
Kind of action for auxiliary relay
CL; Ht
cL
Pr2
SAA
Set Point for auxiliary relay
-50,0÷110°C / -58÷230°F
0,0
Pr2
SHy
Differential for auxiliary relay
0,1
25.5°C/ 1
255°F
2,0
Pr2
ArP
Probe selection for auxiliary relay
nP / P1 / P2 / P3/P4
nP
Pr2
Sdd
Auxiliary relay operating during defrost
n÷y
n
Pr2
ALP
Alarm probe selection
nP; P1; P2; P3; P4
P1
Pr2
ALc
Temperat. alarms configuration
rE= related to set;
Ab = absolute
Ab
Pr2
ALU
MAXIMUM temperature alarm
Set
110.0°C; Set÷230°F
110,0
Pr1
ALL
Minimum temperature alarm
-50.0°C
Set/ -58°F
Set
-50,0
Pr1
AFH
Differential for temperat. alarm recovery
(0,1°C÷25,5°C) (1°F÷45°F)
2,0
Pr2
ALd
Temperature alarm delay
0
255 min
15
Pr2
dAO
Delay of temperature alarm at start up
0
23h e 50’
1,3
Pr2
AP2
Probe for temperat. alarm of condenser
nP; P1; P2; P3; P4
P4
Pr2
AL2
Condenser for low temperat. alarm
(-55 ÷ 150°C) (-67÷ 302°F)
-40
Pr2
AU2
Condenser for high temperat. alarm
(-55 ÷ 150°C) (-67÷ 302°F)
110
Pr2
AH2
Differ. for condenser temp. alar. recovery [0,1°C ÷ 25,5°C] [1°F ÷ 45°F]
5
Pr2
Ad2
Condenser temperature alarm delay
0 ÷ 254 (min.) , 255=nU
15
Pr2
dA2
Delay of cond. temper. alarm at start up
0.0 ÷ 23h 50’
1,3
Pr2
bLL
Compr. off for condenser low
temperature alarm
n(0) - Y(1)
n
Pr2
Label
Name
Range
°C/°F Level
AC2
Compr. off for condenser high
temperature alarm
n(0) - Y(1)
n
Pr2
tbA
Alarm relay disabling
n=no; y=yes
y
Pr2
oA3
Fourth relay configuration
ALr = alarm; dEF = do not select
it; Lig =Light; AUS =AUX;
onF=always on; Fan= do not
select it; db = neutral zone; cP2
= second compressor; dF2 = do
not select it; HES = night blind
Lig
Pr2
oA4
Fifth relay configuration
ALr = alarm; dEF = do not select
it; Lig =Light; AUS =AUX;
onF=always on; Fan= do not
select it; db = neutral zone; cP2
= second compressor; dF2 = do
not select it; HES = night blind
onF
Pr2
AoP
Alarm relay polarity (oA3=ALr)
oP; cL
cL
Pr2
i1P
Digital input polarity (13-14)
oP=opening;CL=closing
cL
Pr1
i1F
Digital input 1 configuration (13-14)
EAL, bAL, PAL, dor; dEF; Htr,
AUS
dor
Pr1
did
Digital input alarm delay (13-14)
0÷255min
15
Pr1
i2P
Digital input polarity (13-19)
oP=opening;CL=closing
cL
Pr2
i2F
Digital input configuration (13-19)
EAL, bAL, PAL, dor; dEF; Htr,
AUS
EAL
Pr2
d2d
Digital input alarm delay (13-19)
0÷255min
5
Pr2
Nps
Number of activation of pressure switch
0 ÷15
15
Pr2
odc
Compress and fan status when open
door
no; Fan; CPr; F_C
F-c
Pr2
rrd
Regulation restart with door open alarm
n – Y
y
Pr2
HES
Differential for Energy Saving
(-30°C÷30°C) (-54°F÷54°F)
0
Pr2
Hur*
Current hour
0 ÷ 23
-
rtc
Min*
Current minute
0 ÷ 59
-
rtc
dAY*
Current day
Sun ÷ SAt
-
rtc
Hd1*
First weekly holiday
Sun÷ SAt – nu
nu
rtc
Hd2*
Second weekly holiday
Sun÷ SAt – nu
nu
rtc
ILE*
Energy Saving cycle start during
workdays
0 ÷ 23h 50 min.
0
rtc
dLE*
Energy Saving cycle length during
workdays
0 ÷ 24h 00 min.
0
rtc
ISE*
Energy Saving cycle start on holidays
0 ÷ 23h 50 min.
0
rtc
dSE*
Energy Saving cycle length on holidays
0 ÷ 24h 00 min.
0
rtc
Ld1*
1
st
workdays defrost start
0 ÷ 23h 50 min. - nu
6.0
rtc
Ld2*
2
nd
workdays defrost start
0 ÷ 23h 50 min. - nu
13.0
rtc
Ld3*
3
rd
workdays defrost start
0 ÷ 23h 50 min. - nu
21.0
rtc
Ld4*
4
th
workdays defrost start
0 ÷ 23h 50 min. - nu
0.0
rtc
Ld5*
5
th
workdays defrost start
0 ÷ 23h 50 min. - nu
0.0
rtc
Ld6*
6
th
workdays defrost start
0 ÷ 23h 50 min. - nu
0.0
rtc
Sd1*
1
st
holiday defrost start
0 ÷ 23h 50 min. - nu
6.0
rtc
Sd2*
2
nd
holiday defrost start
0 ÷ 23h 50 min. - nu
13.0
rtc
Sd3*
3
rd
holiday defrost start
0 ÷ 23h 50 min. - nu
21.0
rtc
Sd4*
4
th
holiday defrost start
0 ÷ 23h 50 min. - nu
0.0
rtc
Sd5*
5
th
holiday defrost start
0 ÷ 23h 50 min. - nu
0.0
rtc
Sd6*
6
th
holiday defrost start
0 ÷ 23h 50 min. - nu
0.0
rtc
Adr
Serial address
1÷247
1
Pr2
PbC
Kind of probe
Ptc; ntc
ntc
Pr2
onF
on/off key enabling
nu, oFF; ES
oFF
Pr2
dP1
Room probe display
--
-
Pr2
dP2
Evaporator probe display
--
-
Pr2
dP3
Third probe display
--
-
Pr2
dP4
Fourth probe display
--
-
Pr2
rSE
Real set
actual set
-
Pr2
rEL
Software release
--
1.8
Pr2
Ptb
Map code
--
Pr2
* Only for model with real time clock
2