- 37 -
Digital Video
Installation Manual
Power Input
System Controller
Main Controller/Local Power Supply
Riser/Landing Controller
Working Voltage
Amplifier
Controller Outputs
Lock Release (Fail Secure)
Lock Release (Fail Safe)
Auxiliary Supply
Battery Back Up:
System & Riser Controllers
12V7Ah Sealed Lead Acid Battery
Main Controllers
12V17Ah Sealed Lead Acid Battery
Power Specification
230VAC
230VAC
50VAC
12VAC
6-12VDC
12VDC (Normally Open)(Rated 1Amp)
12VDC (Normally Closed)(Rated 1Amp)
3 x 12VDC (Rated 3Amp overall)
System Controller Default Settings..
The following system functions are selected by using the FUNCTION and DATA dil
switches located on the Controller motherboard below the Digital Trade clock.
Each of the above switches contains 8 ON and 8 OFF positions that can be selected in
various combinations to achieve varying system functions.
Available Default Functions for Functional and Digital Entrances:
Controller Settings:
Default settings for all functions
Setting line number for apartment
Serial link set up
Medium Volume Electronic Call
Privacy Time
Strobe
Entrance Door 1 (Adjustable Time Functions)
Lock Release time
Telephone Ringing time
System active duration time
Door Open Alarm delay time
Door Open Alarm duration time
Entrance Door 2 (Adjustable Time Functions)
Lock Release time
Telephone Ringing time
System active duration time
Door Open Alarm delay time
Door Open Alarm duration time
Digital Video
Revision 1.08 Date: 05/01/2009