background image

- 14 -

Digital Video 

Installation Manual

Digital Entrance Panel Programming Instructions cont...

System Function Programming cont...

Press 8 on the Digital Panel keypad and then press the 

PROG

 button.

Enter from 1 to a maximum of 9 depending on the position of the Digital Panel in  the system 
and press 

CALL.

If required a set Panel position can be deleted by using the 

CANCEL

 button.

This will set the Digital Panel position in a Single or Multi Entrance system.

Press 9 on the Digital Panel keypad and then press the 

PROG

 button.

The display will now scroll through all connected Controller Interfaces  on the system
 only pausing when data continuity is broken.

This will establish all Controllers have continuity of Data.

Press 10 on the Digital Panel keypad and then press the 

PROG

 button.

The display will now show the factory default setting as shown on the rear of the Digital panel. If there is a 
requirement to change the default mode then press 

CANCEL

, enter the new code number and press 

CALL

 

to accept the change.

                       

Press 27 on the Digital Panel keypad and then press the 

PROG

 button. This will put the system into 

erase mode. Erase mode will be indicated by the Display initially reading 

E.000

 and then following on 

with a count of 30. The system will not reset itself to default at 30. To initiate the default setting, 
the batteries must be disconnected and the Fused spur must be switched off. This must be for a period 
of no less than 5 seconds or the extinguishing of the on board healthy LED’s 

Once instigated the erasing of the system cannot be stopped until completion (Approximately 
90 seconds).

  

Note:
Default settings are as follows,

Function 1     Lock Time                               10 seconds
Function 2     Door Alarm Delay Time           OFF
Function 3     Door Open Duration Time       OFF
Function 4     Service Access Code              Blank
Function 5     Engineers Access Code          Blank
Function 6     Telephone Ring Time              30 seconds
Function 7     Call Duration Time                  30 seconds
Function 8     Digital Panel Position No.       1
Function 10   Panel Facility Configuration   007 (

No Door Open Tones

Note:

Function 8 (Setting Digital Panel Number(s)

Function 9 (Data Communication Test Facility)

Function 10 (Panel Facility Configuration)

Function 27 (Erase All Memory and Reset System to Default)

On a Multi  Entrance system it is important that all Digital Panels are 
assigned an individual position number (FUNCTION 8) AFTER 
Downloading system data.

Non Alpha
A
AB
ABC
ABCD
ABCDE
ABCDEF

Concierge with 

Panel & Lobby 

Camera 

without Door

Open Tone

006
014
022
030
038
046
054

Concierge with 
Panel  & Lobby 

Camera 

with Door

Open Tone

070
078
086
094
102

110
118

Non Concierge

Panel & Lobby 

Camera 

without Door

Open Tone

007
015
023
031
039
047
055

Non Concierge

Panel & Lobby 

Camera 

with Door

Open Tone

071
079
087
095
103

111

119

Digital Video

Revision 1.08 Date: 05/01/2009

Содержание SelectLine Video 16 Digital

Страница 1: ...ectLine Selectine Select Manufacturing Limited Unit H1 The Seedbed Centre Wyncolls Road Severalls Business Park Colchester Essex CO4 9HT Telephone 44 0 1206 855800 Facsimile 44 0 1206 855801 E mail sa...

Страница 2: ...Digital Video Installation Manual Engineers Notes...

Страница 3: ...Digital Systems Digital Video Installation Manual...

Страница 4: ...Current 4 5 6 DIGITAL SYSTEMS WIRING DETAIL Privacy Privacy Indicator and Door Monitoring Amplifier Wiring Detail Dual Landing Panel Display Wiring Detail Camera and Video Distributor Wiring Detail T...

Страница 5: ...Telephone Handset to Strobe Sounder Controller to Door Release Monitor Contacts Systems to Door Release ac and dc Controller to Emergency Override Switch Controller to Request To Exit Button System W...

Страница 6: ...or 0V 0V 0V MFL VC2 Mains Fail MFL 12V 12V 12V B B TC TC ON 1 2 3 4 5 6 7 8 ON 1 2 3 4 5 6 7 8 PANEL 1 3 4 5 6 7 8 9 10 11 12 13 14 15 16 1 2 1 CC DML SBL LS FCL LS1 LS2 SA SE LC LS 2 RTE T RTE T RTE...

Страница 7: ...INE 5 LINE 6 LINE 7 LINE 8 LINE 9 LINE 10 LINE 11 LINE 12 LINE 13 LINE 14 LINE 15 LINE 16 1 C 2 6 9 PS PL DL LINE 3 5 Amp Fuses System Supply Indicator 0V 0V 0V MFL VC2 Mains Fail MFL 12V 12V 12V B B...

Страница 8: ...Digital 50VAC Main Power Supply Overview Digital Video Installation Manual 6 230VAC to 50VAC Supply Fused Spur 50VAC Rail to a Controller AC2 5Amp Fuse AC1 Digital Video Revision 1 08 Date 05 01 2009...

Страница 9: ...16 1 2 PAC1 PAC1 PAC Entrance 1 Input PAC Entrance 1 Input 0 PANEL 2 1 CC DML SBL LS FCL LS1 LS2 SA SE LC LS 2 PAC2 PAC2 0 PAC Jumpers See page 11 PAC Jumpers See page 11 Telephone Door open Tone ON...

Страница 10: ...upply Indicator 18VDC Distributor Supply 12VDC Camera Supply 18 24VDC Monitor Supply 8 12V 12V 0V 0V 9 16 Output To Video Distributors Video Output To Next Controller Digital Panel 2 Input Digital Pan...

Страница 11: ...1 C 2 6 9 PS PL DL 1 C 2 6 9 PS PL DL 1 C 2 6 9 PS PL DL 1 C 2 6 9 PS PL DL 1 C 2 6 9 PS PL DL 1 C 2 6 9 PS PL DL 1 C 2 6 9 PS PL DL 1 C 2 6 9 PS PL DL 1 C 2 6 9 PS PL DL 1 C 2 6 9 PS PL DL 1 C 2 6 9...

Страница 12: ...9 PS PL DL 1 C 2 6 9 PS PL DL 1 C 2 6 9 PS PL DL 1 C 2 6 9 PS PL DL 1 C 2 6 9 PS PL DL 1 C 2 6 9 PS PL DL 1 C 2 6 9 PS PL DL 1 C 2 6 9 PS PL DL 1 C 2 6 9 PS PL DL CC DML SBL RTE RTE FS FS SA SE LC LA...

Страница 13: ...1 SA for Normally Closed and LS1 SE for Normally Open This will give Volt free contacts when a Lock release is initiated from the Telephone Monitor or system RTE is pressed For Fail Secure SE Lock Rel...

Страница 14: ...ce Panel 1 Camera TC TC SIG SCN Emergency Override Switch For Fail Safe SA Lock Releases Common 1 Normally Open 4 Normally Closed 2 R T E N C N O SA LC Main or Landing Video Controller Landing Entranc...

Страница 15: ...ion 1 09 Date 15 12 2010 Digital Panel 1 Input To PAC Controller CamDP1 Functional Video Panel with DDA display wiring detail Video Entrance Panel PANEL 1 3 4 5 6 7 8 9 10 11 12 13 14 15 16 1 2 Brown...

Страница 16: ...ard A G R T RS232 D C B RS475 RS232 Transmission Input Output RS485 Transmission Input Output Concierge Building Interface Card Multi Building wiring detail PC Input Output Controller 2 Interface Card...

Страница 17: ...5 6 7 8 2 DATA SWITCH FUNCTION SWITCH FUNCTION SWITCH FUNCTION SWITCH FUNCTION SWITCH 1 2 3 4 5 FUNCTION SWITCH 1 1 3 3 4 4 5 5 6 6 7 7 8 8 2 2 DATA SWITCH DATA SWITCH Controller Controller Controlle...

Страница 18: ...5 digit engineering code has already been entered the Digital Panel will display EA1 alternating with the remaining 4 numbers i e EA1 2345 This can if required be deleted by pressing the CANCEL butto...

Страница 19: ...To initiate the default setting the batteries must be disconnected and the Fused spur must be switched off This must be for a period of no less than 5 seconds or the extinguishing of the on board hea...

Страница 20: ...e programming mode Note 1 When there is a need to edit or check an already programmed flat on the system use the following procedure Enter Controller number i e 2 Enter Line Output number i e 03 and p...

Страница 21: ...ta Output Data Output 0volts Positive External Alarm Strobe Sounder Negative External Alarm Strobe Sounder Fail Safe Lock Release Output Fail Secure Lock Release Output Lock Release Common 12 24VAC DC...

Страница 22: ...ite White of Blue White of Brown Brown of White Orange of White 2 5mm Mains Type Cable 2 5 Mains Type Cable Brown of White White of Brown Blue of White White of Blue Orange of White Green of White Dig...

Страница 23: ...d Door Monitoring Indicator wiring detail 1 6 CA 9 10 2 PS PL DL Blue of White White of Blue White of Orange and Orange of White White of Green Green of White Brown of White White of Brown System Cont...

Страница 24: ...t Programming Button _ 1 2 12V 0V SCN SIG CAM2 Lobby 12V 0V SCN SIG CAM1 Panel TC TC SIG Entrance Panel Camera 1 SCN Main and Riser Controller Video Board 12 18VDC Distributor Supply Vout Scn CamR Cam...

Страница 25: ...ay Video Distribution Box Distributor Remove all jumpers except the LAST Distributor in the Video Distribution Box 19A Digital Entrance Panel Video Output to Cam DP on next Riser Controller U1 U2 E U5...

Страница 26: ...ntinuity Video Coax To Riser Controller VOUT Distribution Supply To Riser Controller 4 8 12 and 16 Video Distribution wiring detail U1 U2 E U5 U3 U4 Video Distributor R2 R1 U1 U2 E U5 U3 U4 Video Dist...

Страница 27: ...Video Monitor connection plate RD R3 R2 1 2 6 CA R1 R1 V4 V5 V3 10 9 X1 X2 Y1 Y2 Video Monitor wiring detail Distributor Remove all Jumpers on the Distributors except the LAST in line Normally remove...

Страница 28: ...Timed Intercall Digital RTE Request To Exit Button 12VDC Auxiliary Output wiring detail PANEL 1 OV OV OV 12V 12V 12V 12VDC Auxiliary Output 12VDC Auxiliary Output 3Amp Overall Output 12VDC Auxiliary O...

Страница 29: ...release power This is to protect the System Controller against back EMF If the locks are being powered by a PAC Controller then use the MOV supplied with the PAC reader DC Fail Safe Lock Release wirin...

Страница 30: ...B DCIN L L Lock1 Relay 1 Reader1 V LED RTE DC SIG GND N C COM N O L L PAC EASIKEY 1000 System Controller The RED LED s must always be illuminated on both jumpers except on lock release PANEL 1 PAC PAC...

Страница 31: ...GND Relay 2 N C COM N O B B DCIN L L Lock1 Relay 1 Reader1 V LED RTE DC SIG GND N C COM N O L L PAC EASIKEY 1000 PAC DDA READER DO CLK 0V VCA D1 SIG 10 5 28V 1 2 VE VE 12V 12V 0V Sw1 Prog Sw2 Up Load...

Страница 32: ...Cam1P Scn Cam1L Scn Cam2L Scn Camera Supply x 2 Monitor Output Trades Clock Secondary Trades Clock Secondary Trades Clock Auxiliary Supplies 3 x 0V Output 3 x 12VDC Output Power Input to Controller 12...

Страница 33: ...ly 18VDC Monitor Supply Entrance Panel Amplifier Detail Speaker Microphone 6VDC 6VDC Entrance Panel Detail Door Monitor Release Indicator Button Common Trades Detail Trades Button Trades Button Reques...

Страница 34: ...Distributor Supply 0V Distributor Supply Video Inputs and Outputs SML2021 4 Video Signal Output to Distributor Video Screen Output to Distributor Video Riser Signal Output Video Riser Screen Output Vi...

Страница 35: ...Serial link set up Medium Volume Electronic Call Privacy Time Call with Strobe Landing Entrance Door 1 Adjustable Time Functions Lock Release time Telephone Ringing time System active duration time D...

Страница 36: ...nd the DATA switches to select the number of seconds for the ringing time duration Select the ring time duration using the TIME SELECTION seconds chart See Controller Programming Instruction Repeat fo...

Страница 37: ...P P 0 0 1 E P P P P 0 1 0 E P P P P 0 0 0 E P P P P 1 0 0 E 1 0 0 0 0 0 1 0 0 1 0 0 0 0 1 0 S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S 1 0 0 0 0 1...

Страница 38: ...ion Time Entrance Panel 2 15 M inutes 4 0 1 0 0 0 0 1 1 1 1 1 1 1 1 0 0 Note 1 ON X Any Position 1 If an Extension Sounder or Strobe are required set Data switch 8 to ON 0 OFF S Seconds 2 Do not set a...

Страница 39: ...The output status will change and indicate override is in operation by flashing Programming Only two setting buttons are required and Change Program In normal usethe Change Buttonis used to switch ON...

Страница 40: ...anges to show the relay state and the day of the week for a few moments The right hand 8 digits shows the time in HH MM 24 hour format The colon flashes to show the clock is running The last digit sho...

Страница 41: ...34 Digital Video Revision 1 08 Date 05 01 2009 Digital Video Installation Manual Engineers Notes...

Страница 42: ...6 CC TR TR Note The CC connection on the Controller to the Entrance Panel button common should always be a pair I e Slate of Red and Red of Slate Controller to Entrance Panel Amplifier Controller 1 2...

Страница 43: ...is the first colour stated above The banding is the second colour stated above Therefore a wire stated as Black of Slate would be a Black main colour with a Slate banding Lock Release Fail Safe DC Loc...

Страница 44: ...switches located on the Controller motherboard below the Digital Trade clock Each of the above switches contains 8 ON and 8 OFF positions that can be selected in various combinations to achieve varyin...

Страница 45: ...tivate the system timer and illuminate the Privacy On indicator stopping all incoming calls for a timed period You can at any time if you wish cancel the timed Privacy period by pressing the Privacy O...

Страница 46: ...nt Name Commissioning Engineer Installer Name Site Address Telephone No Controller No Comments SELECT General System Comments Please use reverse Trades On On On On Off Off Off Off Trades settings Flat...

Отзывы: