background image

- 32 -

Digital Trades Clock Operating Instructions

Change Button

 

Sets Hours, Minutes
 and Trade Times 
 

 

 

 

 

Programme Button

 

Used to select the clock time and the 4 
On/Off programmed times and to review 
them once set

 

iii. Press the 

Program Button

 once 

 clock is now 

 

set and display shows ready for the first ON 

 

programme time with ON and the hours digit 

 

flashing.

 

 

3. To Set Programme ON/OFF Times

 

(After clock setting)

 

 

Program 1 ON time

 

i. Press 

Change Button

 to advance the hour setting.

 

 

ii. Press the 

Program Button

 once to select the 

 

minute time 

 display shows minute digits and ON 

 

Flashing. Press 

Change Button 

to advance the 

 

minute setting. 

Note:

 16 hours shown as example

 

of hours set).

 

 

iii. Press the 

Program Button

 once – the first ON 

 

time is now set and the display will show ready for 

 

the first OFF programme time.

 

 

iv. Now set the hours and minutes as before.

 

 

v. Repeat steps I to iv to set the remainder of the 3 ON /OFF times as 
required. 

Note: 

Any unused ON/OFF programs should be skipped until 

the display shows normal operating mode. Do not program ‘0’s into 
unused programs.

 

 

4. Program Review

 

To fast review the set program or for quick exit to normal operating
mode press and hold the 

Program Button

 

5. Initiating Programme Mode

 

This can be initiated at any time during the normal operating mode. Press 

Program Button

 and the clock, hours and minutes symbols on the display 

will flash – this is the review mode. If any change to the programmes is 
required press the 

Change Button

 to initiate programme mode and then 

follow steps 2 and 3.

 

 

6. Cancelling Programmes

 

Any ON/OFF programme can be cancelled by 

 

clearing its ON and OFF time. Follow step 5 and 

 

when into the ON/OFF programme to be cancelled 

 

press the 

Change Button

 until the digits show 

 then press the 

Program 

Button

 to clear the programme. The display will show the hour and minute 

digits and ON or OFF flashing.

 

 

Self Cancelling Override

 

To change the output status from ON to OFF or vice versa during normal 
operation press the 

Change Button

. The output status will change and 

indicate override is in operation by flashing.

 

Programming 

 

Only two setting buttons are required, 

 and 

Change

Program 

In normal use the 

Change Button

 is used to switch ON or OFF 

overriding the time switch until the next program ON or OFF 
time. During programming the 

 Change Button

  is used to set the 

Hours and Minutes. The 

Program Button

  is only used when setting 

or adjusting the clock

   Time or the 4 programmed ON/OFF times, 

although it can be used to review the ON/OFF times once they 
have been set.. Each time the 

 

Program Button

  is pressed the 

display will flash either the hours or minutes in turn, starting with 
the clock, then the first  

  ON time, first OFF time, second ON time 

etc. 
Wherever the hours or minutes are flashing they maybe set using 
the 

Change Button

. Once the 

Program Button

 is pressed again to 

proceed to the next stage. 

 

Normal Operating Mode

 

In normal operation the time clock will display the 

 

correct time with the colon flashing. The output 

 

status will be shown be either ON or OFF on the 

 

display.

    

 

1. To Reset Display Mode

 

To clear programme from memory and reset the 

 

time controller press and hold down both buttons 

 

un

til the display goes blank. Release buttons and 

 

the display will fill with its complete range of 

 

characters and then clear to show the clock and hour digit flashing.

 

Programming Sequence

 

Setting Clock

 

 

 

 

Programme 1 ON

 

 

 

Programme 3 ON

 

Programme 1 OFF

 

 

 

Programme 3 OFF

 

Programme 2 ON

 

 

 

Programme 4 ON

 

Programme 2 OFF

 

 

 

Programme 4 OFF

 

 

 

 

 

Operating Mode

 

Note:

 

Button pauses greater than 0ne minute during programming will result in 
automatic return to the operating mode.

 

 

2. Setting Clock (after reset)

 

i. Hour setting 

 Press the 

Change Button

 to 

 

advance the hour setting. 

Note:

 For rapid hour 

 

selections press and hold the 

Change Button.

 

 

ii. Minute Setting 

 Press the 

Program Button

 once 

 

to select the minutes 

 display shows clock symbol 

 

and minute digits  flashing. Press the 

Change 

 

Button

 to advance the minutes setting. 

 

Note:

 For rapid minute selection press and hold the 

Change Button

 

(16 hours shown as example of hours set).

 

 

Output Status 

Showing Trades 
ON or OFF 

Digital Video 

Installation Manual

Digital Video

Revision 1.08 Date: 05/01/2009

Содержание SelectLine Video 16 Digital

Страница 1: ...ectLine Selectine Select Manufacturing Limited Unit H1 The Seedbed Centre Wyncolls Road Severalls Business Park Colchester Essex CO4 9HT Telephone 44 0 1206 855800 Facsimile 44 0 1206 855801 E mail sa...

Страница 2: ...Digital Video Installation Manual Engineers Notes...

Страница 3: ...Digital Systems Digital Video Installation Manual...

Страница 4: ...Current 4 5 6 DIGITAL SYSTEMS WIRING DETAIL Privacy Privacy Indicator and Door Monitoring Amplifier Wiring Detail Dual Landing Panel Display Wiring Detail Camera and Video Distributor Wiring Detail T...

Страница 5: ...Telephone Handset to Strobe Sounder Controller to Door Release Monitor Contacts Systems to Door Release ac and dc Controller to Emergency Override Switch Controller to Request To Exit Button System W...

Страница 6: ...or 0V 0V 0V MFL VC2 Mains Fail MFL 12V 12V 12V B B TC TC ON 1 2 3 4 5 6 7 8 ON 1 2 3 4 5 6 7 8 PANEL 1 3 4 5 6 7 8 9 10 11 12 13 14 15 16 1 2 1 CC DML SBL LS FCL LS1 LS2 SA SE LC LS 2 RTE T RTE T RTE...

Страница 7: ...INE 5 LINE 6 LINE 7 LINE 8 LINE 9 LINE 10 LINE 11 LINE 12 LINE 13 LINE 14 LINE 15 LINE 16 1 C 2 6 9 PS PL DL LINE 3 5 Amp Fuses System Supply Indicator 0V 0V 0V MFL VC2 Mains Fail MFL 12V 12V 12V B B...

Страница 8: ...Digital 50VAC Main Power Supply Overview Digital Video Installation Manual 6 230VAC to 50VAC Supply Fused Spur 50VAC Rail to a Controller AC2 5Amp Fuse AC1 Digital Video Revision 1 08 Date 05 01 2009...

Страница 9: ...16 1 2 PAC1 PAC1 PAC Entrance 1 Input PAC Entrance 1 Input 0 PANEL 2 1 CC DML SBL LS FCL LS1 LS2 SA SE LC LS 2 PAC2 PAC2 0 PAC Jumpers See page 11 PAC Jumpers See page 11 Telephone Door open Tone ON...

Страница 10: ...upply Indicator 18VDC Distributor Supply 12VDC Camera Supply 18 24VDC Monitor Supply 8 12V 12V 0V 0V 9 16 Output To Video Distributors Video Output To Next Controller Digital Panel 2 Input Digital Pan...

Страница 11: ...1 C 2 6 9 PS PL DL 1 C 2 6 9 PS PL DL 1 C 2 6 9 PS PL DL 1 C 2 6 9 PS PL DL 1 C 2 6 9 PS PL DL 1 C 2 6 9 PS PL DL 1 C 2 6 9 PS PL DL 1 C 2 6 9 PS PL DL 1 C 2 6 9 PS PL DL 1 C 2 6 9 PS PL DL 1 C 2 6 9...

Страница 12: ...9 PS PL DL 1 C 2 6 9 PS PL DL 1 C 2 6 9 PS PL DL 1 C 2 6 9 PS PL DL 1 C 2 6 9 PS PL DL 1 C 2 6 9 PS PL DL 1 C 2 6 9 PS PL DL 1 C 2 6 9 PS PL DL 1 C 2 6 9 PS PL DL CC DML SBL RTE RTE FS FS SA SE LC LA...

Страница 13: ...1 SA for Normally Closed and LS1 SE for Normally Open This will give Volt free contacts when a Lock release is initiated from the Telephone Monitor or system RTE is pressed For Fail Secure SE Lock Rel...

Страница 14: ...ce Panel 1 Camera TC TC SIG SCN Emergency Override Switch For Fail Safe SA Lock Releases Common 1 Normally Open 4 Normally Closed 2 R T E N C N O SA LC Main or Landing Video Controller Landing Entranc...

Страница 15: ...ion 1 09 Date 15 12 2010 Digital Panel 1 Input To PAC Controller CamDP1 Functional Video Panel with DDA display wiring detail Video Entrance Panel PANEL 1 3 4 5 6 7 8 9 10 11 12 13 14 15 16 1 2 Brown...

Страница 16: ...ard A G R T RS232 D C B RS475 RS232 Transmission Input Output RS485 Transmission Input Output Concierge Building Interface Card Multi Building wiring detail PC Input Output Controller 2 Interface Card...

Страница 17: ...5 6 7 8 2 DATA SWITCH FUNCTION SWITCH FUNCTION SWITCH FUNCTION SWITCH FUNCTION SWITCH 1 2 3 4 5 FUNCTION SWITCH 1 1 3 3 4 4 5 5 6 6 7 7 8 8 2 2 DATA SWITCH DATA SWITCH Controller Controller Controlle...

Страница 18: ...5 digit engineering code has already been entered the Digital Panel will display EA1 alternating with the remaining 4 numbers i e EA1 2345 This can if required be deleted by pressing the CANCEL butto...

Страница 19: ...To initiate the default setting the batteries must be disconnected and the Fused spur must be switched off This must be for a period of no less than 5 seconds or the extinguishing of the on board hea...

Страница 20: ...e programming mode Note 1 When there is a need to edit or check an already programmed flat on the system use the following procedure Enter Controller number i e 2 Enter Line Output number i e 03 and p...

Страница 21: ...ta Output Data Output 0volts Positive External Alarm Strobe Sounder Negative External Alarm Strobe Sounder Fail Safe Lock Release Output Fail Secure Lock Release Output Lock Release Common 12 24VAC DC...

Страница 22: ...ite White of Blue White of Brown Brown of White Orange of White 2 5mm Mains Type Cable 2 5 Mains Type Cable Brown of White White of Brown Blue of White White of Blue Orange of White Green of White Dig...

Страница 23: ...d Door Monitoring Indicator wiring detail 1 6 CA 9 10 2 PS PL DL Blue of White White of Blue White of Orange and Orange of White White of Green Green of White Brown of White White of Brown System Cont...

Страница 24: ...t Programming Button _ 1 2 12V 0V SCN SIG CAM2 Lobby 12V 0V SCN SIG CAM1 Panel TC TC SIG Entrance Panel Camera 1 SCN Main and Riser Controller Video Board 12 18VDC Distributor Supply Vout Scn CamR Cam...

Страница 25: ...ay Video Distribution Box Distributor Remove all jumpers except the LAST Distributor in the Video Distribution Box 19A Digital Entrance Panel Video Output to Cam DP on next Riser Controller U1 U2 E U5...

Страница 26: ...ntinuity Video Coax To Riser Controller VOUT Distribution Supply To Riser Controller 4 8 12 and 16 Video Distribution wiring detail U1 U2 E U5 U3 U4 Video Distributor R2 R1 U1 U2 E U5 U3 U4 Video Dist...

Страница 27: ...Video Monitor connection plate RD R3 R2 1 2 6 CA R1 R1 V4 V5 V3 10 9 X1 X2 Y1 Y2 Video Monitor wiring detail Distributor Remove all Jumpers on the Distributors except the LAST in line Normally remove...

Страница 28: ...Timed Intercall Digital RTE Request To Exit Button 12VDC Auxiliary Output wiring detail PANEL 1 OV OV OV 12V 12V 12V 12VDC Auxiliary Output 12VDC Auxiliary Output 3Amp Overall Output 12VDC Auxiliary O...

Страница 29: ...release power This is to protect the System Controller against back EMF If the locks are being powered by a PAC Controller then use the MOV supplied with the PAC reader DC Fail Safe Lock Release wirin...

Страница 30: ...B DCIN L L Lock1 Relay 1 Reader1 V LED RTE DC SIG GND N C COM N O L L PAC EASIKEY 1000 System Controller The RED LED s must always be illuminated on both jumpers except on lock release PANEL 1 PAC PAC...

Страница 31: ...GND Relay 2 N C COM N O B B DCIN L L Lock1 Relay 1 Reader1 V LED RTE DC SIG GND N C COM N O L L PAC EASIKEY 1000 PAC DDA READER DO CLK 0V VCA D1 SIG 10 5 28V 1 2 VE VE 12V 12V 0V Sw1 Prog Sw2 Up Load...

Страница 32: ...Cam1P Scn Cam1L Scn Cam2L Scn Camera Supply x 2 Monitor Output Trades Clock Secondary Trades Clock Secondary Trades Clock Auxiliary Supplies 3 x 0V Output 3 x 12VDC Output Power Input to Controller 12...

Страница 33: ...ly 18VDC Monitor Supply Entrance Panel Amplifier Detail Speaker Microphone 6VDC 6VDC Entrance Panel Detail Door Monitor Release Indicator Button Common Trades Detail Trades Button Trades Button Reques...

Страница 34: ...Distributor Supply 0V Distributor Supply Video Inputs and Outputs SML2021 4 Video Signal Output to Distributor Video Screen Output to Distributor Video Riser Signal Output Video Riser Screen Output Vi...

Страница 35: ...Serial link set up Medium Volume Electronic Call Privacy Time Call with Strobe Landing Entrance Door 1 Adjustable Time Functions Lock Release time Telephone Ringing time System active duration time D...

Страница 36: ...nd the DATA switches to select the number of seconds for the ringing time duration Select the ring time duration using the TIME SELECTION seconds chart See Controller Programming Instruction Repeat fo...

Страница 37: ...P P 0 0 1 E P P P P 0 1 0 E P P P P 0 0 0 E P P P P 1 0 0 E 1 0 0 0 0 0 1 0 0 1 0 0 0 0 1 0 S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S 1 0 0 0 0 1...

Страница 38: ...ion Time Entrance Panel 2 15 M inutes 4 0 1 0 0 0 0 1 1 1 1 1 1 1 1 0 0 Note 1 ON X Any Position 1 If an Extension Sounder or Strobe are required set Data switch 8 to ON 0 OFF S Seconds 2 Do not set a...

Страница 39: ...The output status will change and indicate override is in operation by flashing Programming Only two setting buttons are required and Change Program In normal usethe Change Buttonis used to switch ON...

Страница 40: ...anges to show the relay state and the day of the week for a few moments The right hand 8 digits shows the time in HH MM 24 hour format The colon flashes to show the clock is running The last digit sho...

Страница 41: ...34 Digital Video Revision 1 08 Date 05 01 2009 Digital Video Installation Manual Engineers Notes...

Страница 42: ...6 CC TR TR Note The CC connection on the Controller to the Entrance Panel button common should always be a pair I e Slate of Red and Red of Slate Controller to Entrance Panel Amplifier Controller 1 2...

Страница 43: ...is the first colour stated above The banding is the second colour stated above Therefore a wire stated as Black of Slate would be a Black main colour with a Slate banding Lock Release Fail Safe DC Loc...

Страница 44: ...switches located on the Controller motherboard below the Digital Trade clock Each of the above switches contains 8 ON and 8 OFF positions that can be selected in various combinations to achieve varyin...

Страница 45: ...tivate the system timer and illuminate the Privacy On indicator stopping all incoming calls for a timed period You can at any time if you wish cancel the timed Privacy period by pressing the Privacy O...

Страница 46: ...nt Name Commissioning Engineer Installer Name Site Address Telephone No Controller No Comments SELECT General System Comments Please use reverse Trades On On On On Off Off Off Off Trades settings Flat...

Отзывы: