Selecon 5.5-13 Скачать руководство пользователя страница 8

Pacific Operation Manual 

 

 

 

 

 

 

 

Version 4 October 2010 

 

 

Operating your luminaire 

Please note that  as the  handles  and knobs on the Pacific range  can reach  high temperatures 
depending  on  the  position  or  orientation  of  the  luminaire,  and  that  gloves  should  always  be 
worn when focusing these luminaires. 

Pan and Tilt Adjustment   

To pan the luminaire, loosen the nut at the top of the yoke and adjust, then retighten.  To tilt, loosen 
the  locking  clamp  handle  on  the  side  of  the  luminaire,  tilt  and  retighten  finger  tight.  Note  that  the 
maximum tilt angles for the Pacific are 90

 either side of horizontal. 

Focusing Pacific Zoomspot models  

The  beam  of  the  Pacific  can  be  adjusted  to a  well  controlled  soft-
edged  focus  useful  when  merging  one  beam  to  the  next,  or  to  a 
hard-edged focus useful for projections, specials, etc. The variable 
beam  of  your  Pacific  luminaire  is  altered  by  adjusting  the  front  or 
rear lens in relation to each other.  The front lens defines the beam 
spread;  the  rear,  the  focus  degree  of  "softness"  or  "sharpness"  of 
the beam edge or shutters.   

To focus your Zoomspot, first define the beam size required using 
the  front  lens.  Then  set  the  hardness/  softness  of  the  beam  with 
the focus lens. 

Finger tight pressure only is necessary to lock the lens off in their chosen positions. 

Shutter System 

The shutters are used to mask a portion of the beam, shaping it, masking light off scenery, curtains, etc.  Note 
that on the Pacific range of luminaires, the shutters are not removable. The shutter assembly can be rotated 
by loosening the shutter assembly knob on the back of the lens tube, and twisting to the desired position. 
Refasten the knob. Loosen the lamphouse locking knob, and rotate the lamphouse until the top of the heat 
shield is horizontal. Tighten the lamphouse locking knob. 

NOTE: Do not run the luminaire with all the shutters closed, as this may cause the luminaire to over-
heat 

Accessory mounting positions 

The Pacific range provides good image projection right across the beam. The rotatable gobo holder comprises 
the holder and a spring clip to hold the pattern flat against the holder. The holder can be rotated in the slot to 
align the image as required on the stage. 

NOTE:

 The Pacific range has several different pattern holders: 

Gobo holder for 'M' size patterns (5.5-13, 7.5-19 &12-28 Zoomspot) 

 

19PACGHM 

Gobo holder for 'M' size Glass patterns (5.5-13, 7.5-19 & 12-28 Zoomspot) 

19PACGHMG 

Gobo holder for 'A' size patterns (23-50, 45-75 and Fixed Beams) 

 

19ACGHA 

Gobo holder for 'A' size Glass patterns (23-50, 45-75 and Fixed Beams)   

19ACGHAG 

Gobo holder for 'B' size patterns  (14-35 Zoomspot) 

 

 

 

19ACGHB 

Gobo holder for 'B' size Glass patterns (14-35 Zoomspot) 

 

 

19ACGHBG 

Gobo holder for plastic transparencies   

 

 

 

 

19PACGHPLPH 

Iris 

 

 

 

 

 

 

 

 

 

20IRIS 

 
Note that when a ‘B’ size gobo is used in a 12-28, 5.5-13 or 7.5-19 Zoomspot, only 60% of the image area will 
be projected due to the 50mm (2”) gate size. When a ‘B’ size gobo is used in a 23-50 Zoomspot or Fixed 
Beam unit, part of the light beam will be wasted. 

 

Zoom

Focus

 

Содержание 5.5-13

Страница 1: ...E TO PROVIDE YOU WITH A SUPERIOR FITTING IN PERFORMANCE DESIGN ENGINEERING WE ARE CONFIDENT THAT IT WILL PERFORM TO YOUR EXPECTATIONS FOR MANY YEARS TO COME Caution Installation is entirely at your ri...

Страница 2: ...sulting from the customer s failure to follow the installation operating maintenance and safety procedures in this manual or those generally applicable to lighting equipment The foregoing limitation e...

Страница 3: ...further assistance contact your local Philips Selecon dealer or Philips Selecon 2 Safety Warnings 4 Operating your luminaire for the first time 4 Centering the lamp 5 Centre the lamp in the middle of...

Страница 4: ...minaires are not suitable for mounting on a normally flammable surface These luminaires are not suitable for outdoor use They are rated at IP00 The luminaire should be at least 1 0 metre away from the...

Страница 5: ...t is on the ground rather than up in the air Lamp Replacement adjustment Isolate electrically before re lamping the luminaire Also be aware that the lamp or luminaire may still be hot so exercise nece...

Страница 6: ...gear anti clockwise until the distribution appears even across the beam Lamps The Pacific range is available with 5 different lamp holder modules The lamp holder module with a RED handle has a GY9 5 t...

Страница 7: ...es either side of horizontal To mount on a theatre standard scaffold pipe 48mm O D Use a theatre hook clamp Order Code 20HC Your luminaire is supplied with an M12 or for the US set screw two washers a...

Страница 8: ...ains etc Note that on the Pacific range of luminaires the shutters are not removable The shutter assembly can be rotated by loosening the shutter assembly knob on the back of the lens tube and twistin...

Страница 9: ...itted when the accessory is no longer used To fit an accessory in the rear mounting slot Remove the accessory slot cover using a Philips screwdriver Slide the pattern holder against the rear shutter p...

Страница 10: ...losed and lens access knob is securely screwed home All safety anchor bonds are fitted Any accessories are correctly installed and secured Colour frame retention clip is locked down Lamp Module is sec...

Страница 11: ...ips Selecon Return Authorisation Form available from Philips Selecon Return the luminaire to Philips Selecon or its authorised agent If Philips Selecon accepts the warranty claim Philips Selecon will...

Страница 12: ...19PACLM6 Lamp holder module 1000W 19PACLM1 Lamp holder module 575W MSR 19PACLMMSRI Lamp holder module 575W MSR Hot Restrike 19PACLMHRMSR Lamp holder module 80V 1200W inc power supply 18PAC80VASS2 Elec...

Отзывы: