Selecon 5.5-13 Скачать руководство пользователя страница 6

Pacific Operation Manual 

 

 

 

 

 

 

 

Version 4 October 2010 

 

 

 

Centre the lamp in the middle of the beam if necessary, by adjusting the three 
levelling screws. Optimising the output 

The lamp position can be altered to 'Peak' or 'Flat' light output. The peak 
beam gives a central hot spot falling off evenly to the beam edges.  This 
setting  is  useful  for  normal  stage  lighting  purposes  where  beams  are 
overlapped to achieve an even cover.  Flat adjustment provides a visually 
even light beam suitable for gobo projection. Take care to move the lamp 
carefully  as  the  lamp  filament  is  burning  white  hot  and  at  its  most 
vulnerable. Don't over-tighten the knobs; finger tight pressure is all that is 
required. 

 

Adjust the beam to its narrow angle, with a sharp edge. 

Peak the output (turn the centre gear clockwise) until you see 
light flare around the edge of the beam. 

Turn the centre gear anti-clockwise until the flare is removed and you have a clean sharp-edged 
beam. This is the position of maximum light output. 

A useful technique to check how well the lamp is centred is to push two of the shutters into the beam, 
and then check if any reflection off the shutters is visible in the beam. If so, adjust the screw on the 
side opposite to the reflection until it disappears. 

To set a ‘FLAT’ beam, turn the centre gear anti-clockwise until the distribution appears even across 
the beam. 

Lamps 

The Pacific range is available with 5 different lamp holder modules. 

 The lamp holder module with a 

RED 

handle has a GY9.5 type for use with BP1000W 'Blue-pinch' type lamps 

or 650W lamps. Lamps suitable for this module include: 

GAD   1000W Blue Pinch, 220-240V 

 

GAB  

1000W Blue Pinch, 230V 

GAC   1000W Blue Pinch, 115V  
M38 

300W, 2000 hrs  

 

 

M40 

 

500W, 2000 hrs  

T/25, T/18  

500W, 500 hrs    

 

T/26, T/27 

650W, 500 hrs 

 

The  lamp  holder  with  a 

BLUE

  handle  has  a  TP-22  (G9.5)  lampbase  and  is  designed  to  run  with  GKV600 

range of lamps. Lamps suitable for this module include: 

GKV:   600W 220v -240V, 300 hour 

 

GLB:   600W, 240V, 1500 hrs 

GLC:   575W, 115V, 300 hour   

 

GLA:   575W, 115V, 1500 hrs 

GKV:   800W 220v -240V, 300 hour 
 

Important note:

 The GKV range of lamps uses a very compact filament in order to achieve its highly efficient 

output.  For  this  reason,  the  lamp  filaments  are  close  to  each  other  and  are  therefore  sensitive  to  shocks. 
Great care should be taken when adjusting the lamp and focusing the luminaire to avoid shocks. 

For  information  on  the  80V  1200W  lamp  module,  575W  MSR  lamp  module,  and  150W  CDM  lamp  module, 
please refer to the separate instruction sheets. 

 

Important  Note:

  The  quoted  performance  figures  are  achieved  with  Philips  lamps.  Other  manufacturers 

lamps can be used, but no assumptions should be made as to relative performance. 

Please refer to the instructions of the lamp manufacturer when disposing of failed lamps. 

Peak-Flat gear

Lamp tilt gear

 

Содержание 5.5-13

Страница 1: ...E TO PROVIDE YOU WITH A SUPERIOR FITTING IN PERFORMANCE DESIGN ENGINEERING WE ARE CONFIDENT THAT IT WILL PERFORM TO YOUR EXPECTATIONS FOR MANY YEARS TO COME Caution Installation is entirely at your ri...

Страница 2: ...sulting from the customer s failure to follow the installation operating maintenance and safety procedures in this manual or those generally applicable to lighting equipment The foregoing limitation e...

Страница 3: ...further assistance contact your local Philips Selecon dealer or Philips Selecon 2 Safety Warnings 4 Operating your luminaire for the first time 4 Centering the lamp 5 Centre the lamp in the middle of...

Страница 4: ...minaires are not suitable for mounting on a normally flammable surface These luminaires are not suitable for outdoor use They are rated at IP00 The luminaire should be at least 1 0 metre away from the...

Страница 5: ...t is on the ground rather than up in the air Lamp Replacement adjustment Isolate electrically before re lamping the luminaire Also be aware that the lamp or luminaire may still be hot so exercise nece...

Страница 6: ...gear anti clockwise until the distribution appears even across the beam Lamps The Pacific range is available with 5 different lamp holder modules The lamp holder module with a RED handle has a GY9 5 t...

Страница 7: ...es either side of horizontal To mount on a theatre standard scaffold pipe 48mm O D Use a theatre hook clamp Order Code 20HC Your luminaire is supplied with an M12 or for the US set screw two washers a...

Страница 8: ...ains etc Note that on the Pacific range of luminaires the shutters are not removable The shutter assembly can be rotated by loosening the shutter assembly knob on the back of the lens tube and twistin...

Страница 9: ...itted when the accessory is no longer used To fit an accessory in the rear mounting slot Remove the accessory slot cover using a Philips screwdriver Slide the pattern holder against the rear shutter p...

Страница 10: ...losed and lens access knob is securely screwed home All safety anchor bonds are fitted Any accessories are correctly installed and secured Colour frame retention clip is locked down Lamp Module is sec...

Страница 11: ...ips Selecon Return Authorisation Form available from Philips Selecon Return the luminaire to Philips Selecon or its authorised agent If Philips Selecon accepts the warranty claim Philips Selecon will...

Страница 12: ...19PACLM6 Lamp holder module 1000W 19PACLM1 Lamp holder module 575W MSR 19PACLMMSRI Lamp holder module 575W MSR Hot Restrike 19PACLMHRMSR Lamp holder module 80V 1200W inc power supply 18PAC80VASS2 Elec...

Отзывы: