Description of boards 33
9.10) FRONT PANEL BOARD 15.14.236 (fig. 31)
This pair of interconnected boards acts as a user interface, gives the gas solenoid valve and HF striking command, and provides
operating logic and microprocessor control of the whole machine.
Panel boards 15.14.236 have different factory settings depending on the version of the panel they are fitted on (FP106
for G200 TLH or FP 122 for G200AC/DC); this setting can be performed at the factory only.
See section 5.5 for connection of remote control.
DIP SWITCH SETTINGS
1
2
3
4
Genesis 200 TLH
0
1
1
1
Genesis 200 AC/DC
0
1
1
0
Note: connection to the metal structure (and hence with earth potential) of the panel with the yel-
low/green wire is essential to protect the board from disturbance!
CN1:
2
wire n° 52 solenoid valve control ground
3
wire n° 53
torch trigger
4
wire n° 54
torch trigger
5
wire n° 44
HF control signal
6
wire n° 48
HF control earth
8
wire n° 58
+48Vdc solenoid valve control
CN2:
1
wire n° 41 +24 Vdc panel power supply
2
wire n° 42
panel power supply ground
3
wire n° 45
+48 Vdc panel power supply
Unless otherwise specified, all measurements sholud be taken with the boards in their slots and connected accordingly
Содержание Genesis 200 AC-DC
Страница 1: ...REPAIRS MANUAL E N G L I S H Genesis 200 AC DC Genesis 200 TLH WU 15...
Страница 15: ...Description of diagnostic indications 15 Board 15 14 256 only for G 200 AC DC fig 12 G 200 TLH fig 13...
Страница 16: ...16 16 Description of diagnostic indications 7 2 INTERNAL DIAGNOSTIC INDICATIONS Board 15 14 250 fig 14...
Страница 42: ...42 11 AVAILABLE SPARE PARTS 11 1 GENESIS 200 AC DC fig 32 42 Available spare parts...
Страница 44: ...44 44 Available spare parts 11 2 GENESIS 200 TLH fig 33...