SEL-3360-2 Data Sheet
Schweitzer Engineering Laboratories, Inc.
4
Applications
Virtualization for HMI and Other
Applications
Figure 2 SEL-3360-2 OS and Application
Virtualization Platform
Create your own virtualization appliance by leveraging
Intel Virtualization Technology (VT-x) to allow one
hardware platform to function as multiple “virtual” plat-
forms. Isolate your automation controlling activity onto
separate virtual machines to maintain productivity and
realize improved manageability and reduced downtime.
For example, run a virtualized OS specifically for your
HMI or other essential but noncritical applications.
Should your HMI require that the system be restarted,
simply restart the virtual machine and avoid an outage
for your other critical processes. Similarly, multiple
SEL-3360-2 automation controller platforms may be vir-
tualized and entire operating systems transparently
migrated from one physical SEL-3360-2 to another for
hardware upgrades, security or software updates, or test-
ing purposes.
Control System Applications
Use the SEL-3360-2 for process control applications,
including as an HMI or for protocol conversion and high-
speed control when working with other SEL products
and solutions.
Figure 3 High-Speed Control With SEL M
IRRORED
B
ITS
and IEC 61850 GOOSE Communications
Security Applications
Improve security with a single sign-on, enabled through using
the SEL-3360-2 as a local Lightweight Directory Access
Protocol (LDAP) server. Centrally manage user accounts and
group memberships with Microsoft Active Directory or with
your choice of back-end database support.
Figure 4 SEL-3360-2 as Remote Read-Only Domain
Controller Performing Central Authentication Using LDAP
Disturbance Recording System for
PRC-002-2
Figure 5 Reliable Hardware for Running Your
Disturbance Recording System
Event Collection Applications
Figure 6 IED Event Collection With Optional
AC
SEL
ERATOR
T
EAM®
SEL-5045 Software
SEL-3360
Operating System
Application
SEL-
3360
Virtualization
App
OS
App
OS
App
OS
App
OS
Traditional Architecture
Virtual Architecture
CPU
3360
6
33
33
R
421
SEL Rela
y
RTAC
R
421
R
421
R
421
R
421
421
R
421
2730M
Other IED
D
SEL Rela
y
SEL Rela
y
Other IED
D
SEL Rela
y
GOOSE
Messaging
R
R
R
R
R
R
R
R
R
T
T
A
TT
C
Web-
B
sed HMI
ase
se
se
SEL Rela
ys or
Other IEDs
SEL Rela
ys or
Other IEDs
Ethernet S
witch
M
IRRORED
B
ITS
Communications
DNP3
, M
,
odbus
Log in as Alic
e.
Engineering Station
3505
User A
dministr
ation
Yes.
No.
Is Alic
e an authoriz
ed user
?
Is R
ob an authoriz
ed user
?
Log in as R
ob.
Connection est
ablished.
Connection r
efused.
CPU
3360
6
33
33
SE
SE
SE
SE
L-
L-
L
L-
35
3
3
35
Is Ali
ce a
3505
35
35
e a
LD
LD
LD
LD
AP
AP
AP
AP
S
S
S
S
e
e
r
r
r
r
r
v
v
v
v
v
v
v
er
e
2401
SEL-487E Station Phasor
Measurement Unit
SOE Data
As Many as 18 CT Inputs
As Many as 6 PT Inputs
As Many as 55 Digital Inputs
SEL-2401
Satellite-S
ynchr
oniz
ed
Clock
CPU
3360
6
33
33
DDR Data
FR Data
R
487E
M
R
351S
CPU
3360
6
33
33
3505
R
351S
R
351S
R
351S
R
351S
R
351S
3610
Events C
ollec
ted
Automatically
Analyz
e, Contr
ol,
and I
ntegrat
e