DIP Switch SW2 Settings
CAUTION
· Be careful when configuring settings. Marks will be misread if the settings are incorrect.
· Make sure the power is off when configuring settings.
: Indicates the factory settings.
Contents of setting
SW2
No. of lines
Timing type
1
2
3
4
5
6
7
8
12 lines
Control type
ON
ON
ON
OFF
Direct-under type
OFF
OFF
OFF
ON
Mark-to-mark type
OFF
OFF
ON
ON
24 lines
Control type
OFF
OFF
ON
OFF
Direct-under type
ON
OFF
ON
OFF
Mark-to-mark type
ON
ON
OFF
OFF
32 lines
Control type
OFF
ON
OFF
OFF
Direct-under type
ON
ON
OFF
ON
Mark-to-mark type
OFF
ON
OFF
ON
38 lines
Control type
OFF
ON
ON
ON
Direct-under type
ON
ON
ON
ON
40 lines
Control type
OFF
OFF
OFF
OFF
Mark-to-mark type
ON
OFF
OFF
OFF
Direct-under type
ON
OFF
OFF
ON
48 lines
Direct-under type
ON
OFF
ON
ON
Automatic sheet discharge
ON
ON
OFF
OFF
Sheet empty detection
ON
ON
OFF
OFF
Timing mark error detection
ON
ON
OFF
OFF
(Not used)
-
ON
-
OFF
SW2-1 to 4: Select the number of lines to read and the timing mark type according
to the sheet used. Mark-to-mark type is set for “Without top-end margin
reading.”(Reference: “OMR Glossary” (P.45) - Timing control type, Direct under
type, Mark to mark type)
Priority is given to the settings from the computer side.