Maxima MPG Cod. EM00136006
rev. 1.1
30
−
Manual Mode (Man) (see Fig. 29)
Having selected “Man” mode push the
Cal
key.
No strokes will be made
and cc value for the previous
calibration or the default setting will be displayed.
Use the
▲
or
▼
keys to set the quantity of product expressed in
cc
. Values for the various pump models
can be found in
Table 1
. This value can be set between 0,1 and 999,9 cc.
Press the Cal key to save the settings and to return to display mode. The pump returns to its status before
calibration.
−
Default Mode (Def) (see Fig. 29)
Having selected “Def” mode push the
Cal
key.
No strokes will be made
and cc value for the default setting
will be displayed. The value displayed
cannot be edited
.
Press the
Cal
key to save the settings and to return to display mode. The pump returns to its status before
calibration.
Table 1:
Reference values for calibration
Press
u
re
cc
d
o
sed
Mod
el
bar cc
10 0.13
6 0.14
611
3 0.15
7 0.35
4 0.38
612
1 0.58
18 0.31
16 0.35
911
11 0.39
10 0.59
6 0.68
912
2 0.76
5 1.39
4 1.67
913
3 1.85
2 2.43
1 3.06
914
0 4.38