Maxima MPG Cod. EM00136006
rev. 1.1
23
3.2.4
1:c Manual Mode
In this Mode the pump does a settable number of strokes, C, on receiving an input impulse. This impulse may
come from the outside (plunger impulse counter) or by pressing the
▲
key on the keyboard.
To select
1:c MANUAL
mode, push the
Prog
key and hold it down. PrG appears on the screen for a few
seconds, and then the main programming menu will open (
STOP
icon flashing). Push the
▲
and
▼
keys until
F1c appears on the screen, with the
1:c
icon flashing.
Setting parameters from the 1:c menu.
From the main programming menu, when the
Prog
key is pressed the
1:c
icon stays lit and a specific menu
opens, as per the diagram shown below.
Fig. 26:
1:c Manual Mode Menu
To exit Programming and save the parameters set at any time, hold the
Prog
key down for three seconds.
−
Selecting Impulses (See Fig. 26)
The number
c
displayed indi
c
ates the number of strokes the pump doses for each external impulse received or
each time (
▲
) is pressed on the keyboard. This value can be changed, between 1 and 9999 using the
▲
or
▼
keys.
The set value is confirmed by pressing the
Prog
key and the programming moves on to selecting the
Memory
function.
F1 c
Prog
c
Prog
Prog
1..9999
Prog
Memory
on/off
Flow
on/off
Press
the
Press the
key
Press
the key
Press
the key
Press
the
k
i
Press
the keys
Press
the keys