Maxima MPG Cod. EM00136006
rev. 1.1
20
Displaying and Operation
On exiting programming the 100% default value will be displayed (
%
icon lit).
The number displayed shows the percentage flow for each stroke dosed by the pump, for every n external signals
received.
The
n:1
and
%
icons are on and the
STOP
icon must be off while the pump is running.
The value displayed can be edited (between 100% and 1%) by pushing the
Mode
key and the
▲
or
▼
keys
together.
The settings return to their default values each time the setting for the number of impulses is changed on entering
programming. If this parameter is not edited the previous settings are reinstated.
EXAMPLE: setting n = 4
With n=4, if the pump is working at 100% it doses 1 stroke for every 4 external signals received.
If the percentage is set at 80% the pump doses 1 stroke every 5 external signals received (the flow rate will
be 80% of the initial flow rate).
If the percentage is set at 50% the pump doses 1 stroke every 8 external signals received (the flow rate will
be 50% of the initial flow rate).