background image

Thank you very much for purchasing our LED lighting fittings.
Please read this instruction manual to use the product properly.

1) Prior to installing the fitting, check if the product is as per your order.

2) Check for a loose or damaged part due to an accident in transit, etc. 

1)

<1>

<2>

<6>

<1,1H>

<1>

<4>

<1>

<2>

<6>

<1,1H>

<1>

<4>

2) Usable in hazardous areas where there may be deflagrative or flammable dust.

-  Installation work should be done properly by a qualified electrician in accordance with the related laws and the instruction manual.

-  For safety, Installation work should be done by at least two workers.

Direct Mount Type, Pipe Pendant Type, Bracket Type (Fig. 1: Example LKAB070341)

NB:  For the bracket type, fix it on a vertical mounting surface securely.

Screw the pipe into the lamp house.  

Screw the terminal box cover into the pipe.

NB1:

NB2: Caulk the threaded connections.

NB3:

LKAB

After installing the product, be sure to hand this manual over to the user of the product. 

Performance

11E0200002A11

To be conserved

Instruction Manual

Prior to use

Dust Ignition proof type LED Lighting Fittings

LKAB07034

LKAB07035

LKAB07031

LKAB07032

IP

rating

IP65

Type of

protection

SDP-13

LKAB07024

LKAB07025

LKAB07021

LKAB07022

Installation Type

Model

Direct mount 

Pipe pendant

Bracket

Stanchion

Pipe pendant

Bracket

Input Voltage

(Frequency)

Input

Current

Power

Consumption

100-242V AC

(50/60Hz)

0.26-0.12A

0.19-0.08A

25.5-26W

18-18.5W

Stanchion

Special direct mount

Horizontal pole mount 

Lamp house replacemen

The electrical characteristic data is given below (the figure in angle brackets < > in the Installation Type column is a sign placed at the end of
each model code to represent the type of installation.)

Names of the Components and Installation Method

Special direct mount

Horizontal pole mount 

Lamp house replacemen

Direct mount 

Fix the terminal box on a horizontal mounting surface securely with M6
bolts or equivalent bolts.

Lift the lamp house and hook the suspension hook onto the suspension
hook hole of the terminal box.

After connection of the electric wires (white and black: power wires,
green: grounding wire), remove the suspension hook and put it in the
terminal box cover.

Fasten the terminal box and its cover with four cross recessed hexagon
bolts.

After adjusting the positions of the lamp house and terminal box,
tighten the three locking screws.

The pipe, locking screws and cross recessed hexagon blots should be
tightened securely.  Otherwise, the lamp house might fall.

For the direct mount and Pipe pendant type, The lamp house may
be installed within an angle range of 0° (down).

For the bracket type, the lamp house may be installed within an
angle range of 0° (down) to 45° (oblique). For the direct mount and
Pipe pendant type, The lamp house may be installed within an angle
range of 0° (down).

Terminal box 

Suspension hook 

Pipe 

3-Locking screws 

Lamp house 

4-

φ holes for M6  olts

 

Suspension hook hole 

Cover gasket 

Terminal box cover 

4-Cross recessed 
hexagon bolts 

Fig. 1 

-   -

Содержание LKAB07034

Страница 1: ...A 0 19 0 08A 25 5 26W 18 18 5W Stanchion Special direct mount Horizontal pole mount Lamp house replacemen The electrical characteristic data is given below the figure in angle brackets in the Installation Type column is a sign placed at the end of each model code to represent the type of installation Names of the Components and Installation Method Special direct mount Horizontal pole mount Lamp ho...

Страница 2: ...g The lamp house is installed within an angle range from 0 to 70 degrees in the left and right directions For angle adjustment loosen the two hexagon socket head bolts on the retainer After adjustment be sure to tighten the hexagon socket head bolts As shown in Fig 5 put the mounting band onto the support and insert the horizontal pole handrail Lift the lamp house and fix the lamp house mounting b...

Страница 3: ...xisting pipe Attach the protective tube to the connecting member then screw the cover into the body securely Confirm that the cover is invisible from the O ring If visible the waterproofness is not ensured How to Use Maintenance Disassembly and Disposal Separate the cable gland into parts as shown in Fig 7 and pass the cable through the cable gland in the following order cover connecting member ca...

Страница 4: ...ribed range from its downward oriented position 0 If the angle is out of the range an insulation failure or electric shock might result For use in an unfavorable location a very hot cold or humid place or a place in which there is strong wind or vibration a salt damage environment or a dusty or corrosive gas atmosphere a special countermeasure should be taken The ambient temperature should be with...

Страница 5: ...ble for the location Use of an unsuitable type apparatus might cause an explosion or fire The ambient temperature should be within the operating temperature range specified in the instruction manual If the product should be used at a temperature higher than specified an early lighting failure or malfunction might occur or an explosion or fire might result If a product must be oriented in a specifi...

Страница 6: ...lace it The LED module design life is 6 0000 hours different from the lighting fitting life when used at an ambient temperature of 30 C 10 hours per day 3 000 hours per year If used at a higher temperature or more hours per year the life would be shortened Have a specialist inspect the product every three years If used for an extended period without inspection a smoke fire or electric shock might ...

Отзывы: