Information
To properly use the operator it is necessary to programme the run-
ning-length and the force.
Using the operator without these
important adjustments may lead to damages on the garage
door and the operator. For test-runs without a garage door
the running-length blocks must be tightened (please refer
to page 8 “Adjusting the running-lenth blocks”).
The programming procedure is done completely automatic with
an automated procedure. The programming-mode needs to be
started first - it will be indicated by the blinking operators’ light.
The quick-reference on this page shows a short summary of the
procedure.
1.) Adjusting the running-length blocks
This step is descriped on page 8, “Adjusting the running-length
blocks”.
(Remark: the blocks are fixed by tightening the
screw).
2.) Starting the programming-mode
Keep the LERN/LEARN button () pressed for 3 seconds - release
it once the operators‘ light begins blinking. The operator is now
running in programming-mode.
3.) Start the learning-cycle
Shortly press the LERN/LEARN button () once again. The operator
now starts three fully automatic measurement-runs:
3.1. First the block for OPENING direction is searched for
3.. Second the operator closes the garage door with low speed
(during this run you may also change the length of the factory
pre-set soft-stop, as described on page 13).
3.3. The operator stops when the garage door ist closed - the
measured running-length is now stored in the memory
3.4. The operator opens the garage door and measures the re-
quired opening-force
3.5. The operator closes the garage door and measures the re-
quired closing-force
3.6. The operator stops in closing position and remains blinking
for a couple of seconds.
Once all the measures values have saved in the memory the opera-
tors’ light stops blinking - now the operator is ready for use.
Procede with the programming of hand-transmitters on page 18.
Programming Running-Length and Force
Printed Circuit Board: Adjustments and Connections
Quick Reference
1.) Adjustment of blocks
The running-length blocks for
opening and closing direction
must be properly adjusted (please
refer to page 8)
.) Start programming
mode
Press the LERN/LEARN button for
approx. 3 seconds. The operators’
light begins blinking - release the
LERN/LEARN button
3.) Start the learning-cycle
Press the LERN/LEARN button
once again shortly: the operator
now starts three fully automatic
measurement-runs.
The learning cycle stops after the three runs. The garage door
is then closed and the operators’ light stops blinking. The pro-
gramming is now complete.
4.) You may now procede with chapter “Remote Control“ on
page 18
INFORMATION:
When the learning-cycles are made as to the procedure
described on this page, then the operator will be pro-
grammed with the standard values for the soft-modes.
Shall the soft-modes be changed or disabled, then please
refer to pages 14+15.
The learning-cycle can be repeated at any time. Running
a new learning-cycle will overwrite the old values and
substitute them with the new ones.
Содержание TS Akku II