background image

1  S-TRAP PROCEDURE — SECURING THE PAN  
 

CONNECTOR IN PLACE

 

Determine the centre of the 

pan

 and mark the centre line on the 

floor and wall.

 

Work out the setout required.  The recommended setout is 
150mm (setout range is 90-190mm).

 

You may need to trim the large end of the plastic 

pan connector

 

to fit the required setout. To trim, first remove the plastic ring and 
rubber seal, then cut pipe to size.  Refit rubber seal and plastic 
ring securely, ensuring a good fit.

 

Position the pan connector into the floor outlet pipe (S-trap).  
The height measurement from the floor to the centre of the pan 
connector is 185mm.

 

Slot the 

threaded section (with flange plate)

 onto the pan 

connector, ensuring that the flange plate is touching the wall. 
You may need to trim the threaded section so that it fits properly.

 

Mark and drill the flange plate holes and secure the plate to the 
wall with fixing screws.  The pan connector is now installed.

2  POSITIONING THE PAN

 

Use the centre line marked on the wall and floor to position the 

pan

 (see Step 1.1).  Push the pan into the installed plastic pan 

connector.It is recommended that wedges are used to support 
the foot of the pan during positioning.

3  CISTERN — COMES SET UP FOR BACK ENTRY  
 

INLET PLUMBING

 

Diagram A shows the cistern as supplied, with the inlet valve and 
flush valve already installed. The flexible hose is ready for Back 
Entry inlet plumbing (see Diagram B). 

 

For Bottom Entry Inlet plumbing, refer to Step  5 and Diagrams C 
and D.

Page 2 of 4

bottom entry inlet port 
hole for flexible hose  
(on both sides of pan)

bracket fixing holes 
(both sides of pan)

bottom entry water 
control holes

cistern/pan 
attachment holes

seat connection holes

cistern outlet pipe hole

All measurements are in millimetres. 
Height dimensions are to base of pan. 
Make allowance for bedding.
This toilet suite can be set up as either Bottom Entry Inlet or Back Entry 
Inlet.

Cistern setup as 
supplied. The end of the 
flexible hose is loose, 
ready to be attached 
to the Back Entry inlet 
nozzle (see Diagram B).

NOTE: FLEXIBLE HOSE NOT 
SUPPLIED.

DIAGRAM A

inlet

valve

cistern

flush valve

plug

(flexible hose not 

supplied)

215

80

440

180

150 rec

150 setout 

recommended
(range 90-180)

 

BACK ENTRY 

INLET OPTION:

½” BSP nipple 
approx 22mm 

projection from 

finished wall

22

690

360

385

85

770

860

360

300

350

220

BACK ENTRY 

setout position for 

½” BSP nipple

Installation Guide

Limni Wall Faced Toilet Suite