6.2.2 Dimensions for Positioning and Fixing the Platen Holder
Figure 6-3 shows the rotation center area of the platen holder which is critical for setting or releasing the
platen unit.
#1
5°5°
10°
28
(M
IN
)
15
0
(M
A
X
)
The shaded area is the position of
platen holder rotation center
22.325 ±0.2
Unit
:
mm
General tolerance for dimensions :
±
0.1
General tolerance for angles :
±
1º
Figure 6-3 Dimensions for Positioning and Fixing the Platen Holder
6-4