25
I-5320-4
■
SPECIFICATIONS
・
Accuracy daily rate
within
±
0.2 second/day
・
Temperature range for
the rated accuracy
+5
℃~
+40
℃
・
Operating temperature range
-10
℃~
+55
℃
・
I/O specification
0.5-second secondary clock output
Two wired system (Only clockwise)
10 secondary clocks can be connected.(120mA or less)
30-second secondary clock output
Three wired system (Clockwise/Counterclockwise)
65 secondary clocks can be connected.(780mA or less)
Digital signal output
Two balanced wired system (RS-422) , One port
Based on NMEA0183
Logger signal output
Five wired system , One port (150mA or less in total)
・
24V(COMMON)
・
30-second polarized signal output (+)
・
30-second polarized signal output (-)
・
Signal output (-) during time-adjusting
・
Signal output (-) during counterclockwise
Alarm signal output
Two wired system , One port (100mA or less)
・
24V(COMMON)
・
Alarm (-)
【
option
】
RS-232C signal output
Two unbalanced wired system (RS-232C) , One port
(The
content
is
the
same as the digital signal output)
・
The way of time adjusting
When power supply is turned on
Key-input and Digital display on the front panel
At normal operation
Reset to “00” sec. by 0-second adjust button
(
±
30 second adjustment)
After the above operation, hands of 0.5-sec. secondary clock will
follow by stop or fast-forwarding.
30-sec. secondary clock will follow promptly.
・
AC power supply
Range of input voltage
AC 85
~
250V
Range of frequency
47
~
63Hz
Power consumption 35W
・
DC power supply
Range
of
voltage
DC
24V
±
10%
Current
consumption
1.4
A
※
Power supply automatically switched from AC to DC system without interruption in case of AC power
failure.
Содержание QC-6M4
Страница 23: ...23 I 5320 4 外形図 EXTERNAL VIEW ...
Страница 27: ......
Страница 28: ...I 5320 4 URL http www seiko sts co jp ...