39
-
■
Software DIP Switch Setting
:
Factory
settings
Interface selection DIP switch
Posi-
tion
Function Setting
Bit7 Not
used 1
Bit6 1
Even 0
Odd
Bit5
Serial Parity
1
None 0
Yes
Bit4 Serial
Flow control
1
Busy 0
Xon/Xoff
Bit3 1
1
0
0
Bit2
Serial
Baud rate
1
115200
0
57600
1
38400
0
19200
Bit1 1
1
0
0
Bit0
Transmission
selection
1
Auto
0
Bluetooth
1
USB
0
Serial
Hints
When “Auto” is selected for transmission selection, the printer recognizes and selects
the connected transmission method.
Depending upon the host computer, the transmission method may not be recognized.
In this case, manually set the transmission method to be used.
When “Auto” is selected for transmission selection, serial transmission is recognized
by DSR signal of the host computer.
Accordingly, serial transmission of the host computer which does not use the DSR
signal cannot be automatically recognized.
In this case, manually set the transmission method to “Serial.”