6-6
6.3 CONNECT THE PRINTER TO FRAME GROUND (FG)
To prevent the thermal head from being damaged by static electricity, it is recommended that the printer is
connected to frame ground (FG).
6.3.1 How to Connect the Printer to Frame Ground (FG)
•
To prevent the thermal head from being damaged by static electricity, connect the FPC terminals 44
and 45 shown in Chapter 4 to the Frame Ground (FG).
•
Connect the signal ground (SG) to the frame ground (FG) using a 1M
Ω
resistor so that the electric
potential of the signal ground (SG) of the thermal head and that of the frame ground (FG) of the
printer are equal.
•
If using a sheet metal material for the door, the door should also be connected to the frame ground
(FG) of the interface board.