REMARKS ON REPAIRING CAL. 7D46A, 7D48A

 

 

 

 

Cal. 7D** is an Automatic Generating System analog quartz watch equipped with 

piezoelectric motor, featuring the perpetual calendar and automatic adjustment function. 

Although Cal.7D** features new functions, the experience of repairing the existing 

KINETIC series watches will be helpful.   
 
In repairing Cal. 7D**, you are requested to have the full knowledge of its functions and 
strictly observe the repairing and checking instructions provided in this guide so that the 
watch will be repaired correctly. 
 

FEATURES OF CAL. 7D46A, 7D48A 

 
Cal. 7D** features the power save function that automatically stops the hands from 
moving if the watch is left untouched for a certain period of time. Even if the watch is in 
this state, the perpetual calendar continues to count the date until the stored electrical 
energy is depleted. When you decide to use it again, swinging the watch several times will 
activate the time relay function, which starts the hands moving quickly to indicate the 
correct time and resume the normal operation. Cal. 7D** is an innovative KINETIC 
model; it conserves the stored electrical energy by stopping the hands while it is not in 
use, and, at the same time, it completely eliminates the cumbersome time setting 
procedure when it is used again.   
 

1. 

POWER SAVE FUNCTION 

 

While the watch is not in use, the hands stop automatically to minimize the electrical 

energy

 

consumed. This is called “the power save function”. Though the hands stop, 

the built-in IC continues to compute the time, keeping the watch ready for the next 
use. 

 

   

<The automatic power save function> 

If the watch is left untouched for approximately 24 hours, the power save function is 
automatically activated. 
 

2. 

TIME RELAY FUNCTION 

 

While the power saving function is working, the built-in IC continues to compute the 

time though the hands stop. As the watch detects a certain amount of electricity 
generated by swinging it, the hands are automatically adjusted to the time retained 
inside the watch, resuming the normal operation. This is called the “time relay 
function”. As it is activated, the hour and minute hands are adjusted first, then, 
followed by the second hand. 

 

By only swinging the watch for 2 to 3 seconds, the time relay function will be 

activated. 

 

(Caution) 

 

It may take approximately up to 64 seconds (32 seconds on average) to activate 

the time relay function. 

 

The accuracy of the time computation by the built-in IC is equivalent to that of 

conventional quartz watches.  Especially when the watch has been left untouched 
for a long time before the time relay function is activated, the time indicated by the 
hands may include a certain amount of time loss or gain within the range of the 
accuracy of the watch (

±

15 seconds per month) that has accumulated during that 

time. 

 

3. 

CONTINUOUS OPERATING TIME 

The continuous operating time varies depending on the stored electrical energy inside 
the watch. In the case that the fully charged watch enters the power save mode, 

  

2

Содержание 7d46A

Страница 1: ...orewarning function Overcharge prevention function Electronic circuit reset switch Train wheel setting device Instant setting device for date calendar Automatic power save function Time relay function...

Страница 2: ...electrical energy consumed This is called the power save function Though the hands stop the built in IC continues to compute the time keeping the watch ready for the next use The automatic power save...

Страница 3: ...en the watch is in power save mode and the date does not change correctly or shows the wrong date the electrical power stored in the rechargeable battery is being depleted Before starting to wear the...

Страница 4: ...rgeable battery unit MT920 3023 24X Insulator for rechargeable battery 4216 541 Case back 1 2 3 4 5 6 7 Remarks on removing the winding stem To remove the winding stem when taking out the movement fro...

Страница 5: ...Crown Case Second hand Minute hand Hour hand Month indicator Dial 24 hour hand 5 Year indicator hand for cal 7D46A...

Страница 6: ...506 Train wheel bridge for calendar 0125 508 Jumper for year 1024 503 Jumper for units digit 1024 500 13 To be removed while assembling To be removed while assembling 1 Supporting pin for alignment 8...

Страница 7: ...wheel for year 0802 507 22 Indicator on wheel for 24h 1021 502 Intermediate wheel for month indicator 0817 515 23 Detection on wheel for 24h 1002 509 24 25 2nd intermediate wheel for calendar 0817 51...

Страница 8: ...ator for piezoelectric motor 4216 540 33 Piezoelectric motor lead plate 0105 502 34 Piezoelectric stator block 4583 500 35 Jumper for month 1024 504 36 Spring for intermediate wheel for month indicato...