7
No.
Name
Description
7
Preset temperature
attainment lamp (Green)
(NOTE2)
Displays that the temperature has attainted the
preset temperature.
Lit: Displays the temperature attains the preset
temperature. (Heater power off)
Unlit: Displays the temperature does not attain
the preset temperature.
8
Time up lamp (Red)
(NOTE3)
Displays the time up state.
Lit: Displays that the heater is turned off due to
the time up.
Unlit: Displays that the timer is in the count up
state. (Heater on)
9
Timer active lamp
Displays the use state of the timer.
Lit: Displays that the timer is in use state.
Unlit: Displays that the timer is not in use state.
(NOTE2)
When the heater temperature dial, F AN (upper) airflow preset dial, and FAN (lower) airflow
preset dial are turned maximum, the preset temperature attainment lamp may not be lit.
The dryer is designed so that the fan’ s airflow power is slightly stronger than the heater ’s
heating power to maximize the drying up performance. (The heater is always turned on
because the preset temperature cannot attain the maximum temperature 60°C.)
Even though the preset temperature attainment lamp is not lit, the temperature attains the
maximum temperature in approx. 20 minutes after turning the breaker on.
(NOTE3)
Even when the time up lamp is lit, the fans (upper and lower) are functioning based on
the preset dials. (The heater is turned of f.)
The preset temperature attainment lamp may also not be turned of f due to remaining
heat.