11
Removing and Attaching the BAT MECHA
If you need to remove the BAT MECHA as in the case of a failure, open the
control panel base and remove the BAT MECHA through the following
procedure.
To reinstall the BAT MECHA, reverse the removing procedure, being certain that
the BAT MECHA is faced in the correct direction.
For instructions on opening the control panel base, refer to the Instruction Manual
of the cabinet.
To prevent electric shock, be sure to turn off the power for the cabinet when
removing or attaching the BAT MECHA.
The above figure does not show the wiring of the volume and its connector (AMP
3P, white).
Remove the wiring connector (AMP 3P, white) located near the volume.
Remove the tamperproof screw clamping the bat center axis on the front side of
the control panel.
Tightening/loosening of the tamperproof screw should use the tamperproof screw
M4 wrench (540-0006-01) that is included as an accessory for the NAOMI
CABINET, NET CITY, and NEW ASTRO CITY cabinet.
The tamperproof screw M4 wrench is not included with the following cabinets:
Versus CITY, New VERSUS CITY, and BLAST CITY.
If the wrench is not available, please order the following part numbers:
• Wrench type (M4): 540-0006-01
• Screwdriver type (M4): 540-0018
Remove the four flange nuts clamping the BAT MECHA body on the back side of
the control panel.
BAT MECHA Part number: 610-0409
Part name: ASSY BAT MECHA
123
123
1
2
3
Содержание Universal Kit
Страница 4: ...2 ASSY CTRL PNL 2A4B2S MB2K2 ENG NOA 20010 01 D 1 2...
Страница 34: ......
Страница 35: ...VISIT OUR WEBSITE...