29
(4) DC Current
Function
Range
Accuracy
A
0~60.0A
±(
1.5%+ 10 dgt)
60.0~400.0A
±(
1.9%+ 5 dgt)
400A~600A
±(
1.9%+ 10 dgt)
Overload protection :
600 Arms
Position Error :
±
1% of reading.
Addition error according to remanence :
1% max. of current crest.
(5) Frequency : Hz
Range
Resolution
Accuracy
20~400Hz
1HZ
±(
0.1% + 2 dgt)
Overload protection :
600 Arms.
Sensitivity :
3 Arms for ACA (A
)
(>400Hz Unspecified)
(6) Peak Hold :
±
(3% + 15dgt)
*>600Vpeak Unspecified.
*>600Apeak Unspecified.
(7) Min/Max Hold :
add
±
15 dgt to accu-
racy for ACA / DCA.
* Automatically switch to the low resolu-
tion range at Peak Hold and MIN MAX
Hold.
(8) Auto Power Off (APO)
The meter will automatically shut itself off
after approximately 30 minutes after power
on.
Содержание MW 3360
Страница 4: ...4 Mesure de tensions DC ou AC Mesure de r sistance...
Страница 5: ...5 Mesure de continuit...
Страница 6: ...6 Mesure de courants AC 590A 390A 190A I I I 0 I I I OK...
Страница 7: ...7 Mesure de fr quence Fonction relative z ro ACA 50Hz...
Страница 8: ...8 Fonction HOLD Fonction Min Max HOLD 0A...
Страница 16: ...16...
Страница 19: ...19 AC V DC V Resistance...
Страница 20: ...20 Continuity...
Страница 21: ...21 ACA DCA 590A 390A 190A I I I 0 I I I OK...
Страница 23: ...23 Data Hold Min Max Hold 0A...