Содержание MW 3360

Страница 1: ...Notice d utilisation User s Manual MW 3360 MW 3365 Pince amp rem trique 600A AC DC 600A AC DC Digital Clampmeter M336X00M00...

Страница 2: ...es ten sions lev es Ne pas utiliser des cordons endom mag s craquelures Utiliser l appareil uniquement dans son domaine de mesure sans d passer les limites indiqu es Lorsque des mesures sont faire sur...

Страница 3: ...mps lectromagn tiques important les indications peuvent tre instables et ou erron es Mise en marche A l aide du commutateur rotatif Arr t automatique Pour inhiber l arr t automatique appuyer sur une t...

Страница 4: ...4 Mesure de tensions DC ou AC Mesure de r sistance...

Страница 5: ...5 Mesure de continuit...

Страница 6: ...6 Mesure de courants AC 590A 390A 190A I I I 0 I I I OK...

Страница 7: ...7 Mesure de fr quence Fonction relative z ro ACA 50Hz...

Страница 8: ...8 Fonction HOLD Fonction Min Max HOLD 0A...

Страница 9: ...imum et minimum des mesures La valeur MAX est affich e MIN idem MAX C est la valeur MIN qui est affich e MAX MIN clignotant la pince m morise les valeurs extr mes C est la valeur courante qui est affi...

Страница 10: ...r te positive P min idem Pmax mais c est la valeur cr te n gative qui est affich e CAL un appui de plus de 3 s entraine une auto calibration de la fonction Mode Normal un nouvel appui permet de retour...

Страница 11: ...Pile 9V type 6F22 alcaline recommand e Autonomie 200 heures avec pile alcaline Ouverture des bras 45mm max Diam tre maximum du conducteur 35mm max ou barre 40x15 mm Coefficient de temp rature 0 2 x Pr...

Страница 12: ...cations lectriques Les pr cisions sont donn es en lecture nombre de digits 23 C 5 C et H R 80 1 Tensions Type Gamme Pr cision V AC 0 400V 400 600V 1 0 5dgt V DC 0 400V 400 600V 0 7 2dgt Imp dance d en...

Страница 13: ...V V 600V 2 R sistances et continuit Gamme R solution Pr cision 400 0 1 1 0 3 dgt Protection 600V eff max Tension en circuit ouvert 3V Continuit le buzzer est actif pour une r sistance inf rieure 30 oh...

Страница 14: ...80 de la gamme ajouter 1 6 la sp cification de pr cision Protection 600A eff max M thode de conversion et erreur additionnelle due au facteur de cr te se reporter au tableau des tensions AC 5 Fr quen...

Страница 15: ...F puis sur la fonction d sir e 9 Remplacement de la pile Lorsque le symbole pile us e est affich proc der au remplacement de la pile selon le croquis en d but de notice Toujours d brancher les cordons...

Страница 16: ...16...

Страница 17: ...perly or if it is wet Use the Meter only as specified in the Instruction card or the protection by the Meter might be impaired Use extreme caution when working around bare conductors or bus bar Contac...

Страница 18: ...h generates electromag netic interference the display may be come unstable or the measurements show may be subject to large errors On Off Auto Power Off Auto Power Off disable Press buttons except Hol...

Страница 19: ...19 AC V DC V Resistance...

Страница 20: ...20 Continuity...

Страница 21: ...21 ACA DCA 590A 390A 190A I I I 0 I I I OK...

Страница 22: ...after press the ZERO button first time The LCD is displaying the relative value REL flashing Meter saved the offset value Present value is displaying Normal Press and hold ZERO for 2 sec to return to...

Страница 23: ...23 Data Hold Min Max Hold 0A...

Страница 24: ...ng the maximum and minimum value Minimum value is displayed MAX MIN flashing Meter is saving the maximum and minimum values Present value is displayed Normal Press and hold MIN MAX to return to normal...

Страница 25: ...d PMIN Meter is saving the peak maxi mum and minimum value Peak minimum value is displayed CAL Press and hold PEAK button 3 sec to calibrate the Meter itself for accurate measurement Normal Press and...

Страница 26: ...ronmental Conditions Indoor Use Calibration One year calibration cycle Operating temperature 0 C 30 C 80 RH 30 C 40 C 75 RH 40 C 50 C 45 RH Storage temperature 20 to 60 C 0 to 80 RH batteries not fitt...

Страница 27: ...on Type 3360 AC Conversion are average sens ing rms indication calibrated to the rms value of a sine wave input 3365 AC Conversions are ac acoupled true rms responding calibrated to the rms value of a...

Страница 28: ...rcuit under test is less than 30 approximately 3 AC Current Function Range Accuracy A 50 60Hz 0 60 0A 1 9 7 dgt 60 0 400 0A 1 9 5 dgt 1 400 600A 2 5 5 dgt 0 60 0A 2 5 7 dgt A 61 400Hz 60 0 400 0A 2 5...

Страница 29: ...Hz Range Resolution Accuracy 20 400Hz 1HZ 0 1 2 dgt Overload protection 600 Arms Sensitivity 3 Arms for ACA A 400Hz Unspecified 6 Peak Hold 3 15dgt 600Vpeak Unspecified 600Apeak Unspecified 7 Min Max...

Страница 30: ...t to repair this Meter It con tains no user serviceable parts Repair or serving should only be performed by quali fied personal 10 Cleaning Periodically wipe the case with a dry cloth and detergent do...

Страница 31: ...SEFRAM 32 rue E Martel F42100 Saint Etienne France Tel 04 77 59 01 01 Fax 04 77 57 23 23 Lignes commerciales 04 77 59 36 81 ou 80 SAV 04 77 59 36 96 Web www sefram fr e mail sales sefram fr...