SERVICE MANUAL
iHunter Series
- 145 -
(20) Put the genuine notes of same denomination with counterfeit on the Hopper as many as
possible. If the rejection rate is over 5%, go to process (24).
(21) If you satisfied counterfeit and genuine level, press and hold down
CF
key.
To enter the CF LEVEL ADJUST Mode, press
CF
key.
(22) Move to NO 3.ADJ LEVEL SAVE and press
key for saving the UV level.
Display show as below.
(23) To exit CF LEVEL ADJUST Mode, press
RESTART
key.
(24) If the rejection rate is over 5%, press and hold down
CF
key.
* * C F L E V E L A D J U S T U S D * *
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
E X I T
1 . C O U N T E R F E I T
2 . G E N U I N E
> > 3 . A D J L E V E L S A V E
4 . D E F A U L T L O A D
< < A d j u s t S a v e O K > >
* * C F L E V E L A D J U S T U S D * *
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
E X I T
1 . C O U N T E R F E I T
2 . G E N U I N E
> > 3 . A D J L E V E L S A V E
4 . D E F A U L T L O A D
< < D i s a b l e > >
CF -> UV, MG
CURRENCY -> IR
CF -> UV, MG
CURRENCY -> IR
Содержание iHunter 2.0 CIS/FIT
Страница 1: ...SERVICE MANUAL iHUNTER Series REV 1 0 ...
Страница 39: ...SERVICE MANUAL iHunter Series 39 5 6 TROUBLE SHOOTING Please ask to factory or agent company ...
Страница 64: ...SERVICE MANUAL iHunter Series 64 13 Remove the IR REAR SENSOR board assembly ...
Страница 93: ...SERVICE MANUAL iHunter Series 93 Click the Continue Anyway button ...
Страница 159: ...SERVICE MANUAL iHunter Series 159 10 Try to insert the new note into the input receptacle as shown in the picture ...