35
9. Dismantling/reassembly
B / 18.12.2017 - OM.MAI.93EN - 9/14
9.1.3.6
Dismantle feed hopper (500)
9.1.3.7
Dismantle rotating unit (RTE)
Dismantle flush connection (SSU) (optional)
Put a protective cover
(SH)
on the rotor
(600)
.
Risk of injury through incorrect
dismantling. Fingers could get crushed when the
stuffing part is repositioned. Use the grips on
stuffing part
(535)
for repositioning.
Dismantle the screw fitting
(538, 539)
.
Remove stuffing part
(535)
and O-ring
(536)
.
Dismantle screw fitting
(590, 591)
.
Remove stator capture
(568)
and o-ring
(569)
.
Risk of injury through incorrect
dismantling. The feed hopper
(500)
can cause
injuries if it falls. Secure the feed hopper
(500)
from falling down.
Remove screw fitting
(562, 563, 564)
.
Remove feed hopper
(500)
and O-ring
(561)
.
Remove flush connection
(SSU)
from the casing
of the shaft sealing
(SEA)
.
Assemble tool
(W10)
as contact surface
for mounting lever
(W9)
.