33
9. Dismantling/reassembly
B / 18.12.2017 - OM.MAI.93EN - 7/14
9.1.3
Dismantle pump
9.1.3.1
Prepare pump for dismantling
9.1.3.2
Dismantle dry-running protection device (TSE) (optional)
Before dismantling the pump, dismantle the dry running protection device
(TSE)
.
–
Observe associated documents (
chapter 12.1) of the operating and
assembly instructions.
9.1.3.3
Dismantle pressure branch (700)
DANGER
Risk of fatal injury from electrical current.
There is an immediate danger of fatal electric shock through contact with live
parts.
Observe safety regulations.
Disconnect the drive from all energy sources.
Prevent electrical connections from being switched on again.
Ensure that residual voltage is not present at any electrical connections of the
machine.
Empty pipelines.
Allow pipelines to cool.
Remove the connections to the pipelines
(CFL)
and the extension hopper
(AST)
(suction side/
pressure side).
Observe de-commissioning instructions
(
chapter 6).
Risk of injury due to lack of stability of
pump. Crushing of body parts due to the pump or
pump parts tipping or falling down.
Fasten base plate
(GPU)
to secure pump.
–
Recommendation: Fasten to suitable base
using a screw fitting
(SCH)
.
Dismantle screw fitting
(SCH)
.
Содержание BTHE 10-12
Страница 2: ......
Страница 6: ......
Страница 16: ...10 ...
Страница 18: ...12 ...
Страница 24: ...18 ...
Страница 52: ...46 ...
Страница 56: ...50 ...
Страница 57: ... Ausgabe issue B 29 03 2011 Dokument document OM SZG 02e Blatt sheet 1 1 10 Spare parts 10 1 Spare parts list ...
Страница 58: ...52 ...
Страница 64: ...58 ...
Страница 66: ...60 ...
Страница 68: ...62 ...
Страница 69: ...63 ...