17
|
ACCESS FOR SERVICING
AND MAINTENANCE
The CW-6S Microcore rooftop unit
should be installed in a position that
allows adequate access for installation,
and future maintenance and servicing
activities. This should comply with
installation guidelines and any local, State
and National regulations.
Consider the following for installation
location:-
• Which is structurally capable of
supporting the weight of the rooftop unit
and service technicians
• Which has clear access to and around
the rooftop unit
•
Which is clear of fixtures in line with
below clearances
• Which is clear of fall edges (> 3m away)
Required clearances around the rooftop
unit for future maintenance and servicing
are shown below.
ILL2987-A
Extra service or warranty charges may
apply for the cost of any equipment
or additional labour involved in
accessing the rooftop unit if these
guidelines are not met.
REMOVING SIDE PANELS
To remove a side panel:
1.
Insert a flat head screw driver into the
gap between the lid and the top of the
side panel. Lever it so the side panel
is released.
2. Remove the clips holding the panel in
place (2 on each corner of the cooler).
Use a screwdriver to lever the clip
from the outside edge.
3. Take hold of the side panel, pivot it
outwards and lift it up.
CW-6S Microcore Rooftop Unit
ILL2987-A
ILL2989-A