TESTING THE COOLER
Once you are satisfied that the cooler is
installed and commissioned correctly, it
is important to run the cooler and
ensure that everything is working as it
should.
Try turning the cooler on and off with
the remote control in all of the rooms in
the house. This will make sure that the
receiver is located correctly.
Check that the cooler runs quietly and
with a balanced distribution of air to all
outlets.
Make sure there are no water leaks.
Initiate a drain of the pan by pressing
the
drain button on the remote
control or
&
button
together on Wall Control.
Check the drain fittings and pipes,
making sure there are no leaks.
DIP SWITCHES
WARNING: Do not alter DIP
switches 1 to 8 on top row and 7 & 8
on bottom row as the cooler will
cease to work.
There are 2 rows of DIP
switches
located under the battery cover on the
remote control.
ON
ON
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
OFF
OFF
ILL217-H
EXAMPLE ONLY
Definition of DIP switch positions (first 6
in bottom row only) are as follows:
(1)
Reserved for later use.
(2)
OFF, 24 hour clock.
ON, 12 hour clock.
(3)
OFF, 1.0, 3/4HP Motor.
ON, Not Used
(4)
OFF, no pre-cool.
ON, pre-cool.
(5)
OFF, drains 3 days after
power off.
ON, drains 3 hours after
power off.
(6)
OFF, drains every 65 minutes
of operation.
ON, activates water salinity
circuit (WaterManager).
SEELEY INTERNATIONAL –
INSTALLATION & OPERATION MANUAL
18
Testing the Cooler