4
|
ELECTRICAL REQUIREMENTS
INSTALLING THE MAINS POWER CABLE
The power cable, included with your cooler will have boot lace
ends ready for connection to the mains power supply.
Means for all pole disconnection must be incorporated in the
fixed wiring in accordance with the wiring rules.
Field Wiring
Pass the power cable through the conduit gland located on
corner of unit.
Terminate the power cable in a junction box installed nearby.
Refer to the field wiring diagram below. The fixed wiring must
be fitted with an all pole disconnection switch that breaks the
active and neutral in accordance with local wiring rules. We
recommend the junction box be located and installed on the
dropper.
WARNING!
Do not let the cable, the cable ends, or the control
box get wet.
ILL2149-A
GROMMET
CONTROLLER
CABLE
POWER
INSTALLING THE CONTROLLER CABLE
Seeley International recommends:
•
Not routing data/communication and supply mains voltage
cables in the same conduit.
•
Not cable tying or taping data/communication and supply
mains voltage cables together.
•
A minimum separation distance, as specified by your
local wiring standards, between data/communication and
supply mains cables. In Australia, this minimum separation
distance is 50mm .
Connect one end of the control cable (with ferrite suppressor) to
the cooler electronics box. The wall control cable can be fitted
to either of the RJ ports
Down Discharge Units
A hole is provided in the side of the blower housing for control
cable entry. The control cable can be passed through this hole
and wired to the control box. On installation pass the cables
through the hole into the dropper and then into the roof cavity
Side & Top Discharge
Using knockout located on the corner pillar on the opposite side
to the mains connection
Feed looped end of the controller cable through the supplied
grommet then fit the grommet into hole left after knock out was
removed.
Note!
It is important to route the control and power cables out
through included grommets / conduit.
Note!
The maximum length for the wall control cable to travel
alongside the power cable is 10m
.
WARNING!
Do not let the cable, the cable ends, or the control
box get wet.
IMPORTANT REMINDER!
Do not route extra-low voltage data/communication and low
voltage supply mains cables without first consulting your local
wiring standards. Routing data/communication cables and
supply mains cables in close proximity can present an electrical
hazard and can be detrimental to the performance of the
product, resulting in intermittent communication errors, locking
up of screens, displays dropping out and inconsistent erratic
operation.
It is required that all units be connected to the mains supply
through an independent circuit, suitably protected by fuse or
circuit breaker. Ensure that the power supply is sufficient for the
rating indicated on the serial plate. Wire the unit in accordance
with all state and local regulations.
NOTE
An all pole disconnection switch must be incorporated in the
fixed wiring in the accordance with the wiring rules.
ILL3005
ILL2149-A
ILL3006