10
|
ILL1664-A
About Appliance
Displays information such as model number, serial number and
software version for all coolers connected to the controller.
Min/Max Set Temperature
Defines the maximum and minimum temperature values.
Night Quiet Mode
Restricts fan speed to a specified level during a specified
period.
Manual Drain
Turns cooler off and drains the tank.
Pad Flush
Turns cooler off and runs pump for a specified amount of time.
Drain And Dry
Cooler will drain and fan will run for 1 hour every day at a
specified time.
Water Manager (If drain kit is fitted)
Select the preferred water management method:
• Salinity Measurement - replaces water when Salinity level
reaches set point.
•
Timed Drain - drains Tank After 8 tank fill cycles or every 1-2
hours (system dependant).
•
No Drain Control - salinity control external to electronics
eg. continuous bleed.
• No Water Thermostatic - allows Thermostatic control in VENT
mode. No water present. Cooling performance is limited.
Weatherseal Open Speed
The cooler fan will turn on at the specified Weatherseal opening
speed for the first 10 seconds each time it starts up. It will then
return to the set fan speed.
Prewet
When COOL mode is activated, the pump will run for 90
seconds before the fan is switched on.
Salinity Level
Sets the salinity level at which the tank will drain in “SALINITY
MEASUREMENT” mode.
Tank Drain Delay
Sets the time delay before the drain valve opens after the pump
in the cooler is turned off.
AutoClean
Select the preferred cleaning interval (50 / 100 / 200 hours).
At 8.00am after the selected running hours has been reached,
the cooler will drain the tank, fill with fresh water and operate
the pump for 5 minutes. When complete, drains the tank and
returns to previous operation mode.
ADJUSTING COOLER SETTINGS
Within the SETTINGS menu of the MagIQtouch Controller is the
COOLER sub-heading. Here various settings of the cooler can
be adjusted.
It is required that all units be connected to the mains supply
through an independent circuit, suitably protected by fuse or
circuit breaker. Ensure that the power supply is sufficient for the
rating indicated on the serial plate. Wire the unit in accordance
with all state and local regulations.
NOTE
An all pole disconnection switch must be incorporated in the
fixed wiring in the accordance with the wiring rules.