Powerstick
6 Programming the DSP
23
6.4.16
RMS time
Definition:
rmstime <time>ms
Description:
Sets the averaging time of the RMS measurement for the limiter. When the
RMS time is not set by the user standard value (35 ms) is set by the DSP. Only
use this function when you know what you are doing.
Example(s):
power 8R 400W 1200W 32dB
rmstime 250ms
# sets the limiter value
# sets an integration time of 250 ms
for the RMS limiter
6.4.17
Peak time
Definition:
peaktime <time>ms
Description:
Sets the averaging time of the peak measurement for the limiter. When the
RMS time is not set by the user standard value (35 ms) is set by the DSP. Only
use this function when you know what you are doing.
Example(s):
power 8R 400W 1200W 32dB
peaktime 50ms
# sets the limiter value
# sets an integration time of 50 ms for
the peak limiter
6.4.18
Volume-Control
Definition:
volcontrol
Description:
The text command „volcontrol“ defines the DSP- or amp channel which whose
volume can be set on the operation panel of the Powerstick. In the whole
Powerstick preset text only the first „volcontrol“ command is regarded by the
DSP. Further „volcontrol“ commands occurring in the preset text are ignored by
the DSP.
Example(s):
out 1
volcontrol
gain +6dB
# defines channel 1 as the channel
whose level can set on the operation
panel