background image

 MR-23006-AT Remote Multiplex Annunciator Panel Wiring and Installation Manual

7

of closed doors; and, smoke and heat detectors may not detect smoke or heat from fires on another level of the 
residence or building. 

Software

Most Secutron products contain software. With respect to those products, Secutron does not warranty that the 
operation of the software will be uninterrupted or error-free or that the software will meet any other standard of 
performance, or that the functions or performance of the software will meet the user’s requirements. Secutron shall 
not be liable for any delays, breakdowns, interruptions, loss, destruction, alteration or other problems in the use of a 
product arising our of, or caused by, the software.

Every fire is different in the amount and rate at which smoke and heat are generated. Smoke detectors cannot 
sense all types of fires equally well. Smoke detectors may not provide timely warning of fires caused by 
carelessness or safety hazards such as smoking in bed, violent explosions, escaping gas, improper storage of 
flammable materials, overloaded electrical circuits, children playing with matches or arson. 

Even if the smoke detector or heat detector operates as intended, there may be circumstances when there is 
insufficient warning to allow all occupants to escape in time to avoid injury or death. 

•Alarm Notification Appliances

 

Alarm Notification Appliances such as sirens, bells, horns, or strobes may not warn people or waken someone 
sleeping if there is an intervening wall or door. If notification appliances are located on a different level of the 
residence or premise, then it is less likely that the occupants will be alerted or awakened. Audible notification 
appliances may be interfered with by other noise sources such as stereos, radios, televisions, air conditioners or 
other appliances, or passing traffic. Audible notification appliances, however loud, may not be heard by a hearing-
impaired person. 

Telephone Lines

 

If telephone lines are used to transmit alarms, they may be out of service or busy for certain periods of time. Also 
the telephone lines may be compromised by such things as criminal tampering, local construction, storms or 
earthquakes. 

•Insufficient Time

There may be circumstances when the system will operate as intended, yet the occupants will not be protected from 
the emergency due to their inability to respond to the warnings in a timely manner. If the system is monitored, the 
response may not occur in time enough to protect the occupants or their belongings. 

•Component Failure

 

Although every effort has been made to make this system as reliable as possible, the system may fail to function as 
intended due to the failure of a component. 

•Inadequate Testing

 

Most problems that would prevent an alarm system from operating as intended can be discovered by regular testing 
and maintenance. The complete system should be tested as required by national standards and the Local Authority 
Having Jurisdiction and immediately after a fire, storm, earthquake, accident, or any kind of construction activity 
inside or outside the premises. The testing should include all sensing devices, keypads, consoles, alarm indicating 
devices and any other operational devices that are part of the system. 

•Security and Insurance

 

Regardless of its capabilities, an alarm system is not a substitute for property or life insurance. An alarm system 
also is not a substitute for property owners, renters, or other occupants to act prudently to prevent or minimize the 
harmful effects of an emergency situation. 

IMPORTANT NOTE: End-users of the system must take care to ensure that the system, batteries, telephone lines, 
etc. are tested and examined on a regular basis to ensure the minimization of system failure. 

Содержание MR-2306-AT

Страница 1: ...T 648SEC WARNING This manual contains information on limitations regarding product use and function and information on the limitations as to liability of the manufacturer The entire manual should be r...

Страница 2: ......

Страница 3: ...ction 2 Controls Displays 2 Wiring Instruction 3 Dip Switch Settings 4 Jumper Selection 4 Specifications Features 5 Enclosure 5 Electrical Specifications 5 Current Drain for Battery Calculations 5 War...

Страница 4: ......

Страница 5: ...yswitch Each Circuit Indicator is a bi colour LED that is automatically configured to match the Fire Alarm Control Panel configuration Technical Support For all technical support inquiries please cont...

Страница 6: ...er Silence Lamp Test 8 Circuit Status LED s Notes The MR 2306 AT is supplied with NP 386 paper labels for zone identification This annunciator displays initiating circuit status only no individual cir...

Страница 7: ...field wiring needs to be of an appropriate gauge for the number of annunciators and the total wiring run length See the specifications section Current Drain for Battery Calculations and calculate the...

Страница 8: ...ess A0 Three digit address of the annunciator address range 1 to 7 inclusive SW1 2 Address A1 SW1 3 Address A2 SW1 4 When SW1 4 is off the System Reset and Signal Silence slide switches are always dis...

Страница 9: ...e Annunciation of up to 8 Points Not Expandable Standby 35 mA Max All LED s On 90 mA Max Current Drain for Battery Calculations The maximum normal current drain will be during Lamp Test when all lamps...

Страница 10: ...operative while it does not have power Power interruptions of any length are often accompanied by voltage fluctuations which may damage electronic equipment such as a fire alarm system After a power i...

Страница 11: ...reos radios televisions air conditioners or other appliances or passing traffic Audible notification appliances however loud may not be heard by a hearing impaired person Telephone Lines If telephone...

Страница 12: ...ble installation environment for the products damage caused by use of the products for purposes other than those for which it was designed damage from improper maintenance damage arising out of any ot...

Страница 13: ...product will be charged for each replacement unit WARNING Secutron Inc recommends that the entire system be completely tested on a regular basis However despite frequent testing and due to but not li...

Страница 14: ......

Страница 15: ......

Страница 16: ...Niagara Falls New York 14305 Tel 888 SECUTRON 888 732 8876 Fax 905 660 4113 No part of this publication may be reproduced transmitted transcribed stored in a retrieval system or translated into any la...

Отзывы: