Security Chimneys HE43-2 Скачать руководство пользователя страница 5

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

5

Figure 1 - Outside air Register

D.

 

Wet wood

 

  Wet or tarred wood will smoulder and smoke 

instead of burning properly. Your dealer can 

help  you  determine  if  you  have  properly 

seasoned wood for burning.

E.

 

Dirty or blocked chimney

  Check to make sure the chimney is clear and 

clean. If dirty call a certified chimney sweep 

or use a properly sized chimney brush to 

clean.

F.  Chimney not long enough

  The minimum chimney height is twelve (12) 

feet (3.7 m) not including the fireplace height.  

The chimney must extend at least three (3) 

feet  (915  mm)  above  its  point  of  contact 

with the roof and at least two (2) feet (610 

mm) higher than any roof or wall within ten 

(10) feet (3 m) of it.  When installed with 

one  offset,  the  minimum  chimney  height 

is fifteen (15) feet.  Additional height will 

increase draft and will decrease the tendency 

to smoke.

G.  Poor chimney draft

  With no fire, there should be sufficient draft 

to exhaust cigarette smoke introduced under 

the chimney.  Chimneys installed against an 

outside wall without protection may generate 

back draft problems which will cause start-up 

problems.    To  prevent  this,  open  a  nearby 

window, roll up a piece of paper and light it.  

Then, hold it in the upper part of the firebox 

to warm up the chimney.  Wait until the draft 

is sufficient, then start the fire.

IMPORTANT CAUTIONS

A. Do not block the hot air vents to the fireplace 

as this will cause the fireplace to overheat.

B. Never use gasoline, gasoline-type lantern 

fuel,  kerosene,  charcoal  lighter  fluid,  or 

similar liquids to start or ‘freshen up’ a fire 

in this fireplace.  Keep all such liquids well 

away from the fireplace while it is in use.

C. Do not burn coal.  The sulphur in coal will 

corrode the firebox and chimney.

D. Keep combustible materials at least 48” 

(1.2 m) away from the front of the fireplace 

opening.

E. Never  leave  children  unattended  when 

there is a fire burning in the fireplace.

F.  Do not use the HE43-2 as an incinerator 

to burn paper, cardboard or construction 

material such as pressed wood, plywood 

or lumber. Use only untreated wood. Wood 

protectors, metallic paper, coal, plastic, 

waste, beach wood, Christmas tree,  sul-

phur and/or oil will damage the fireplace.

G. Do not burn driftwood which has been in the 

ocean or salt water.  The salt will corrode 

the firebox and chimney.

H. Do not burn wood in the area in front of 

the log retainer.

I.  Do not allow the wood to smoulder or burn 

without  flame,  since  this  will  produce 

excessive creosote in the unit as well as 

increased particulate emissions.

Push to open

Push to open

HOW TO USE THE OUTSIDE AIR REGISTER 

(FIREPLACE)

The outside air register is located on the up-

per left part of the top louver.  The outside air 

register supplies oxygen to the fire and allows 

control of the fire when the doors are closed.  

The fresh air must come from outside the house 

(the air intake must not draw air from inside the 

house).  This will minimize negative pressure in 

the house.  The more you slide the register to 

the left, the more fresh air into the firebox and 

the more accelerated combustion you will get 

(see 

Figure 1

).  When starting a fire, the register 

should always be fully opened.

For information on when you should start closing 

the register, see "Refueling" section.

REFUELING

The  HE43-2  fireplace  will  operate  best  if  at-

tention is given to operating the unit with the 

outside  air  register  fully  opened  (see 

Figure 

1

) after refueling in order to bring the firebox 

and the chimney system up to their optimum 

operating temperature.  Combustion efficiency 

is relative to firebox temperature.  To obtain this 

temperature,  the  fireplace  must  be  operated 

with the primary air fully opened during 10 to 

20 minutes after reloading, depending on the 

heat and on the moisture content of the wood.  

Once you have reached the desired temperature, 

the outside air register control  can be set to a 

medium setting.  The benefit of this technique 

will be cleaner glass, less creosoting, greater 

efficiency and the most pleasing fire for your 

enjoyment.

Set the air register to the full open position before 

opening the doors to reduce the possibility of 

smoke entering the home from the fireplace. 

CLOSING THE DOORS

As soon as a layer of embers covers the surface 

under the log retainer, it is possible to close 

the doors with the outside air register opened.

Closing the doors prematurely may result in:

•  The firebox filling with smoke;

•  The flame intensity cuts down excessively.
Meaning  the  fireplace  is  not  hot  enough  to 

close the doors.

SMOKING – 
CAUSES AND TROUBLESHOOTING

To  reduce  the  likelihood  of  smoking  when 

opening the door, set the outside air register to 

the left before opening the door.  Your fireplace 

has been designed and tested to provide smoke 

free operation.  Occasionally, there may be a 

small amount of smoking upon lighting the fire, 

until the chimney heats up but this should not 

continue.  If the fireplace continues to smoke 

it is probably for one of the following reasons:

A.

 

The doors are partially opened

  When  you  open  the  doors,  open  them 

completely.

B.  Negative pressure in the house

  As the fire burns, air goes up the chimney.  

This air must be replaced through leakage 

into the house or through the outside air 

duct.  When operating the HE43-2 fireplace, 

open a nearby window temporarily to check 

if there is adequate replacement air supply.

C.

 

Fans operating (e.g.: range hood)

  Fans such as range hoods or bath fans draw 

air out of the house and may actually cause 

a negative pressure in the house.  Turn off all 

fans and open a nearby window to determine 

if this is the cause of the problem.

Содержание HE43-2

Страница 1: ...continuous use as a primary heat source INSTALLATION AND OPERATION INSTRUCTIONS WARNINGS Hot Do not touch The glass and surfaces of this appliance will be hot during operation and will retain heat for...

Страница 2: ...packag ing woodproductswithsynthetic binders i e plywood Plywood lumber and other misc materi alscanproduceabnormallyhigh temperatures sputtering and smoking fires and may contain hazardous chemicals...

Страница 3: ...an energy effi cient heatcirculatingfireplace Youwillreceive a lifetime of comfort and enjoyment from your fireplaceprovideditisinstalled maintainedand operated properly Please read these instructions...

Страница 4: ...period of one year will usually meet that criteria The required drying time will vary depending on the climate Wood that is packed tight together will take longer to dry Seasoned wood is darker in co...

Страница 5: ...r The outside air register supplies oxygen to the fire and allows control of the fire when the doors are closed Thefreshairmustcomefromoutsidethehouse the air intake must not draw air from inside the...

Страница 6: ...framing Creosote formation in a chimney can be minimized by making sure there is always visible flame burning avoid smouldering fires and by proper refuelling techniques Chimney Maintenance Regular c...

Страница 7: ...s of the hinges supports see fastening screws in Figure 5 If a minor angular adjustment is needed you may loosen only two 2 of the three 3 screws using the other as a pivot point How to use the retrac...

Страница 8: ...NTACT OF GLASS CLEANER WITH THE FIREPLACE FACADE CAN PROVOKE PAINT PEELING OFF Gasket Replacement Remove the doors from the unit see Page 7 andlayeachdooronacleanunabrasivesurface To replace the gaske...

Страница 9: ...hout this manual Please give special attentiontotheseinstructionsasyouprogress with your installation Fireplace Installation Procedure 1 Move the fireplace into the desired position follow the recomme...

Страница 10: ...directly on the floor figure 8B Cold Climate Installations Climates where temperatures will fall below 32 F 0 C The heating performance of the appliance will vary depending upon the level of insulatio...

Страница 11: ...loose filling material CovertheinsulationwithDrywallpanels around the fireplace 7 MIN 2 X 3 MIN A G B Rough Framing Face unfinished shown 593mm 23 11 32 K Combustion Air Kit Combustible materials can...

Страница 12: ...using the same insulation as the rest of the building below the attic Finished wall Must have the same fires rating as adjacent ceiling Must be insulated same as adjacent ceiling Local code regulatio...

Страница 13: ...el 3 The outside air register must not be installed more than 10 feet 3 1 m above the base of the fireplace 4 The outside air assembly must draw air from outside the house It must not draw air from th...

Страница 14: ...nnection Connector for Optional Rheostat Thermodisc Automatic Thermal Blower Activator Figure 14 Central Forced Air Kit central forced air kit If this kit is installed this appliance no longer qualifi...

Страница 15: ...f and at least 2 feet 610mm higher than any wall roof or building within 10 feet 3 m of it see Figure 18 If the chimney extends higher than 5 feet 1500mm above its point of contact with the roof it mu...

Страница 16: ...support 5 Then puttheroofflashinginplaceandseal the joint between the roof and the flashing with roofing pitch For sloping roofs place theflashingundertheuppershinglesandon top of the lower shingles...

Страница 17: ...gths use an offset support halfway up the offset If penetrating a wall install a wall radiation shield see Figure 27 3 Use another elbow to turn the chimney vertically Secure the elbow using three 3 1...

Страница 18: ...Lengths Between Elbows 12 18 36 48 12 48 18 48 36 48 48 48 AC 8 15 A 4 13 16 122mm 6 1 8 156mm 11 280mm 14 1 8 359mm 16 7 8 429mm 18 7 16 468mm 23 584mm 26 3 16 665mm B 27 11 16 703mm 33 1 2 851mm 50...

Страница 19: ...gle Hole Size ASHT 8 I D 30 14 3 8 x 36 1 2 365mm x 927mm Canada Only 45 14 3 8 x 24 3 4 556mm x 629mm S 2100 8 I D 30 16 x 40 406mm x 1016mm Canada Only 45 16 x 27 1 4 406mm x 692mm AC 8 I D 30 15 1...

Страница 20: ...ation refer to the instructions provided with the support Universal Offset Support This support is used to support the chimney above an offset When the chimney offset is used to traverse a wall this s...

Страница 21: ...nded at elevations above 4000 feet or in very cold climates where temperatures are likely to fall below 0 F 18 C When using AC chimney an AC8SB H3801 starter section must be used before installing an...

Страница 22: ...to Convert Fireplace for Use with AC Chimney Starter Section adaptor 8 AC AC8SB H3801 Starter 30 Elbow 8 AC AC8SB30 H3802 Outside Air Kit Chimney Required for AC Chimney Installations Chimney Outside...

Страница 23: ...replace with any material 7 feet measured from the base of the fireplace Except the wood framing See Page 11 Figure 9 Chimney 2 50 mm Mantel 48 1219 mm measured from the base of the fireplace Specific...

Страница 24: ...PR COGR2035 31 and 1 each P N PR COGR2035A 16 v Note To order a complete gasket set to seal one glass on a nickel plated door order one each P N PR ISO2748 P N PR ISO2749 and P N PR ISO2750 Contactan...

Страница 25: ...NOTE DIAGRAMS ILLUSTRATIONS ARE NOT TO SCALE 25 Replacement parts HE43 2 PA I N T 18 1 2 3 4 6 7 9 8 10 10 12 11 13 15 16 14 17 19 20 21 22 5...

Страница 26: ...s should be ordered through your Security Chimneys International distributor or dealer Parts will be shipped at prevailing prices at time of order When ordering repair parts always give the following...