background image

HE43-1 

 

 

Installation and 

Operating Instructions 

for  Security Fireplace 

Model SECURE HE43-1

 

This installation manual will help you obtain 
a  safe,  efficient,  dependable  installation  for 
your  fireplace  and  chimney  system.    Please 
read  and  understand  these  installation 
instructions 

before 

beginning 

your 

installation. 

 

CAUTION:    Do  not  attempt  to  modify  or 
alter  the  construction  of  the  fireplace  or  its 
components.    Any  modification  or  alteration 
of  construction  may  void  the  warranty, 
listings and approvals of this system.  In that 
case,  Security  Fireplace  will  not  be 
responsible for damages. 

 

WARNING: This fireplace is designed for 
use as a supplemental heater.  It is not 
intended for continuous use as a primary heat 
source. 

SAVE THESE INSTRUCTIONS FOR 

FUTURE REFERENCE 

 

 

 

 

2125 Monterey St., Laval, Qc, Canada,  H7L 3T6 

 

Printed in Canada                                                    Rev. 11       November 2008                                                PIHE43-1 

 

 

 

 

Hot!  Do  not  touch!

  The  glass 

and  surfaces  of  this  appliance 
will  be  hot  during  operation 
and will retain heat for a while 
after shutting off the appliance. 
Severe burn may result. 

 

Carefully  supervise  children  in 
the same room as appliance. 

 

 

 

If small children are present in the home, it 
is recommended that this appliance be used 
with a fire screen kit. 

 

 

Listed to standards: 
ULC-S610, UL-127 
Report # 192-5237 

Содержание SECURE HE43-1

Страница 1: ...ase Security Fireplace will not be responsible for damages WARNING This fireplace is designed for use as a supplemental heater It is not intended for continuous use as a primary heat source SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE 2125 Monterey St Laval Qc Canada H7L 3T6 Printed in Canada Rev 11 November 2008 PIHE43 1 Hot Do not touch The glass and surfaces of this appliance will be hot during...

Страница 2: ...CERTIFICATION LABEL W a r n o c k H e r s e y U S C ...

Страница 3: ...uilding supplies 10 Installation procedure 11 Locating the fireplace 11 Adjacent walls 11 Enclosure 11 12 Facing and mantel 12 13 Hearth extension 13 Outside air installation 13 14 UZY5 fan kit installation 15 Fireplace dimensions 16 Central forced air kit 17 Chimney installation General notes 18 Straight installation 19 19 20 21 Offset installation 22 23 24 Angled firestop installation 25 Roof su...

Страница 4: ...sert heating unit may be installed in the fireplace only if this unit has been certified with the HE43 1 fireplace Caution Never use gasoline kerosene charcoal lighter fluid or similar liquids to start or freshen up a fire in this fireplace Keep all such liquids well away from the fireplace at all times Caution Keep combustible materials at least 48 inches away from the front of the fireplace open...

Страница 5: ... avoid damaging the chimney Do not use a brush that could scratch the stainless steel interior of the chimney WARNING The following steps must be followed to sweep the chimney Negligence to do so could cause creosote accumulation on the baffle and in the air circulation area Sweeping steps 1 Remove fireplace top baffle and obstruct dilution air deflector 2 Close chimney damper and doors 3 Sweep 4 ...

Страница 6: ...JUSTMENT Glass doors may lose their adjustment during transportation or installation of the fireplace A wrong adjustment may cause a loss in combustion s efficiency and control The glass doors must be parallel at the same height and must almost touch each other when closed Maximum spacing between the doors is one sixteenth of an inch 1 16 The glass doors can be adjusted by loosening the three 3 sc...

Страница 7: ...cals can corrode the firebox and chimney Do not abuse the unit by burning large amounts of paper cardboard Christmas tree branches or building construction materials such as pressed wood plywood or lumber Intense firing with these may overheat the fireplace causing damage to the unit a fire or even possibly igniting a chimney fire if the chimney is creosoted FIRST FIRES The first 5 or 6 fires shou...

Страница 8: ... closed at the same time Figure 2 HOW TO USE THE OUTSIDE AIR REGISTER FIREPLACE The outside air register is located on the upper part of the top louver The outside air register supplies oxygen to the fire and allows control of the fire when the doors are closed The fresh air must come from outside the house the air intake must not draw air from inside the house This will minimize the risk of causi...

Страница 9: ...vent build up of soot and creosote inspect and clean the chimney periodically during the heating season 6 To prevent possible hazards due to poor combustion and to avoid affecting other fuel burning appliances furnace wood stove etc ensure that the outside air kit is properly installed 7 This fireplace is designed to allow the installation of a gas burner In such a case the installation must confo...

Страница 10: ... Measuring tape Plumb line Electric drill and bits Pliers Square If gas pipe is used Pipe wrench Pipe cutter Pipe threader Pipe joint compound Pipe key valve Building supplies 2 x 3 or heavier lumber Drywall panel or equivalent Silicone caulking non combustible Overlay material for fireplace façade Hearth extension non combustible ...

Страница 11: ...er be directly placed on flat wood plywood particle board or other hard surface materials ADJACENT WALL A wall perpendicular to and in front of the fireplace front facing must be at least 18 460 mm from the fireplace opening A wall at 45º to the front facing and starting at the fireplace s outer edge is permitted Projections within this area are permitted See figure 4 Figure 4 ENCLOSURE 1 WARNING ...

Страница 12: ...s will cause the fireplace to overheat Figure 5 CHASE ENCLOSURE A chase is a vertical box like structure constructed to surround the fireplace and chimney Refer to figure 5b for a typical chase configuration A chase should be constructed and insulated just like any outside wall In a cold climate we recommend the base of the chase should also be insulated between the solid continuous base beneath t...

Страница 13: ...d with non combustible caulking or cement 3 On a raised base or raised hearth a Z shape piece of metal must be fabricated to join the bottom of the fireplace to the floor The supplied metal safety strip must be positioned as follows One half under the fireplace and the other half must extend on the floor over which the hearth extension will be built figure 7b The safety metal strip must cover the ...

Страница 14: ...xible duct is 20 ft 6 1 m If a longer duct is required use a 6 I D 150 mm insulated flexible duct The maximum length is 40 ft 12 m Refer to figures 8b and 8c for connections 2 The duct and register may be installed above or below floor level 3 The outside air register must not be installed more than 10 feet 3 05 m above the base of the fireplace 4 The outside air assembly must draw air from outsid...

Страница 15: ... fireplace side opening 1 from the back of the fireplace 3 Install the automatic fan activator on the side of the firebox the fan activator has a magnetic mount 4 Plug the fan kit into the junction box 5 Ground both fans to the back panel using the green screws NOTE The fireplace must be electrically connected and grounded in accordance with local codes or in the absence of local codes with the cu...

Страница 16: ...ment to quality all specifications ratings and dimensions are subject to change without notice All framing dimensions calculated for dry wall at the fireplace face If sheathing the chase or finishing with other thickness materials calculations will need to be made The fireplace must not be in contact with any insulation or loose filling material Cover insulation with dry wall panels around the fir...

Страница 17: ...exible pipe to the chosen location The ducting system can be installed either in an upper room or in a lower room 4 Attach the flexible pipe to the fan using the collars figure 10a 5 Fix the decorative grill fan adaptor to the fan 6 Attach a standard 3 x 10 grill to the adaptor 7 Install the blower thermostat in that part of the house to be heated by the hot air duct Do not install the blower ther...

Страница 18: ...4 elbows 20 ft 6 10 m Table 1 NOTE A maximum of 2 offsets is allowed NOTE In areas where winter temperatures are normally below freezing the air cooled chimney may produce condensation This condensation may corrode the top of the fireplaces and is not covered under warranty For optimum performance of your fireplace Security Chimneys International recommends the use of an ASHT HT6103 or S2100 HT600...

Страница 19: ...ng section before installing the first chimney length see Figure 15 Continue installing chimney lengths until you reach the desired height Every time the chimney passes through a roof or a wall install the appropriate firestop When you reach the desired height install the roof support see instructions included with the support Then put the roof flashing in place and seal the joint between the roof...

Страница 20: ...20 Figure 14a Figure 14b Figure 15 NOTE THE OUTSIDE AIR KITS ARE MANDATORY FOR BOTH FIREPLACE AND CHIMNEY ...

Страница 21: ... 4 387 mm 16 7 8 429 mm 16 1 8 410 mm 6 12 16 1 8 410 mm 17 7 8 454 mm 16 7 8 430 mm 8 12 17 3 8 441 mm 19 1 4 489 mm 18 1 4 465 mm 10 12 18 3 4 476 mm 20 7 8 530 mm 19 5 8 500 mm 12 12 20 3 8 518 mm 22 5 8 575 mm 21 3 8 545 mm CROSS SLOPE HOLE SIZE PUT THE CHIMNEY CAP INTO PLACE WASH THE ROOF FLASHING WITH A SOLVENT OR VINEGAR THEN PAINT IT WITH RUST PROOF PAINT Table 3 AC CHIMNEY ...

Страница 22: ... bob to line up the centre of the hole Cut a hole for the chimney in the ceiling Frame this hole as described previously see page 17 5 From below install a radiation shield see Figure 14a 6 A support ST or SO must be used on the first 15 section 5 m 7 Continue with the regular installation AC chimney 1 Install the first elbow Turn it in the required direction To lock it in place turn 1 8 of a turn...

Страница 23: ... LENGTHS BETWEEN ELBOWS 8 12 18 24 36 48 8 48 12 48 18 48 24 48 36 48 48 48 Secure Temp S2100 Nova TempHT6000 15º DEVIATION 3 5 16 84mm 4 5 16 110mm 5 7 8 149mm 7 7 16 189mm 10 1 2 267mm 13 5 8 346mm 15 1 2 394mm 16 1 2 419mm 18 1 16 459mm 19 5 8 498mm 22 3 4 578mm 25 13 16 656mm HEIGHT 16 406mm 19 7 8 505mm 25 11 16 652mm 31 1 2 800mm 43 1 16 1094mm 54 5 8 1387mm 61 7 16 1561mm 65 1 4 1657mm 71 1...

Страница 24: ...24 Figure 17 Figure 18 ...

Страница 25: ...da only In cold climate locations we recommend that you use the insulated wall radiation shield since it will maintain the home s thermal barrier RSM and RSMI30 RSMI45 CHIMNEY MODEL ANGLE HOLE SIZE ASHT HT6103 8 I D 30º 14 3 8 x 36 365 mm x 927 mm Canada only 45º 14 3 8 x 24 556 mm x 629 mm S2100 HT6000 8 I D 30º 16 x 40 406 mm x 1016 mm Canada only 45º 16 x 27 406 mm x 692 mm AC 8 I D 30º 15 x 38...

Страница 26: ...ACSL must be used every 40 12 m instead of the ST For roof support installation refer to the instructions provided with the support UNIVERSAL OFFSET SUPPORT INSTALLATION This support is used to support the chimney above an offset When the chimney offset is used to traverse a wall this support may be used on the wall to support the chimney The maximum heights are given in Table 7 For offset support...

Страница 27: ...nstallation where more than one chimney is located in the same chase or within the same general area we suggest that their terminations be separated by at least 16 410 mm horizontally and 18 460 mm vertically This separation is to prevent smoke migrating from one chimney to another see Figure 20 Figure 20 APPENDIX SPECIFICATIONS Weight 343 lbs Height 42 Width 43 Depth 26 5 8 Chimney weight ASHT 8 ...

Страница 28: ...8SB30 Roof brace XBS2 BS2 Wall band XBM BM Firestop Firestop ACBF 8BF Radiation shield ACRS 8RS Attic radiation shield ACRSA 8RSA2 Wall radiation shield 30º ACRSM30 Insulated wall radiation shield 30º ACRSMI30 8RSMI30 Wall radiation shield 45º Insulated wall radiation shield 45º 8RSMI45 Outside air kit chimney ACZI flex insulation outside register and coupling Flat roof flashing ACF 8F Adjustable ...

Страница 29: ...Top louver PR SR15P Bottom louver PR SR15P Louver hinges PR PIVOT Rigid firescreen left PR PARETING 1 Rigid firescreen right PR PARETIND 1 Black door left PR SR2060GNO Black door right PR SR2060DNO Gold plated door left PR SR2060GOR Gold plated door right PR SR2060DOR Brushed nickel door left PR SR2060GBN Brushed nickel door right PR SR2060DBN Wooden handle PR SAC 69 Ceramic glass panel PR VC10 Ce...

Страница 30: ...I x 30 ft long 5FLEX25 Blower for central forced air kit BISZY Fireplace blower include 2 fans and thermostatic control UZY5 Blower variable speed control with decorative wall plate VRUW Thermo disk on off blower control VTU Back draft damper BISBD Flexible pipe fan adaptor with BISBD for BISZY BISAVF ...

Отзывы: