background image

21

OPERATION 

Using Your Garage Door Opener

Your LiftMaster Security

®

opener and hand-held remote

control have been factory programmed to a matching
code which changes with each use, randomly accessing
over 100 billion new codes. Your opener will operate with
several Security

®

remote controls up to 12 functions,

and one Security

®

Keyless Entry System. If you

purchase a new remote, or if you wish to deactivate any
remote, follow the instructions in the 

Programming

section. 

Activate your opener with any of the following:

The hand-held Remote Control:

Hold the large push

button down until the door starts to move.

The wall-mounted Control Console:

Hold the push bar

down until the door starts to move.

The Keyless Entry (See Accessories):

If provided with

your garage door opener, it must be programmed
before use. See 

Programming.

When the opener is activated (with the safety
reversing sensor and cable tension monitor correctly
installed and aligned):

1. If open, the door will close. If closed, it will open.
2. If closing, the door will reverse.
3. If opening, the door will stop.

4. If the door has been stopped in a partially open

position, it will close.

5. If obstructed while closing, the door will reverse. If the

obstruction interrupts the sensor beam, the opener
lights will blink for five seconds.

6. If obstructed while opening, the door will stop.
7. If fully open, the door will not close when the beam is

broken. The sensor has no effect in the opening cycle.

If the sensor is not installed, or is misaligned, the door
will not close from a hand-held remote. However, you can
close the door with the Control Console, the Outside Key
lock, or Keyless Entry, 

if you activate them until down

travel is complete. 

If you release them too soon, the door

will reverse. 

Security

®

light feature:

Lights will also turn on when

someone walks through the open garage door. With a
Motion Detecting Control Console, this feature may be
turned off as follows: Push and hold the light button for
10 seconds and the incandescent light bulbs will blink
once signifying the feature is turned OFF. To turn the
feature back ON push and hold the light button and the
incandescent light bulbs will blink once signifying the
feature is turned ON.

IMPORTANT SAFETY INSTRUCTIONS

To reduce the risk of SEVERE INJURY or DEATH:

WARNING

WARNING

WARNING

1. READ AND FOLLOW ALL WARNINGS AND

INSTRUCTIONS.

2. ALWAYS keep remote controls out of reach of children.

NEVER permit children to operate or play with garage door
control push buttons or remote controls. 

3. ONLY activate garage door when it can be seen clearly, it is

properly adjusted and there are no obstructions to door
travel.

4. ALWAYS keep garage door in sight until completely closed.

NO ONE SHOULD CROSS THE PATH OF THE MOVING
DOOR.

5. NO ONE SHOULD GO UNDER A STOPPED, PARTIALLY

OPENED DOOR.

6. If possible, use emergency release handle to disengage

door ONLY when garage door is CLOSED. Weak or broken
springs or unbalanced door could result in an open door
falling rapidly and/or unexpectedly.

7. NEVER use emergency release handle unless garage

doorway is clear of persons and obstructions.

8. After ANY adjustments are made, the safety reversal

system MUST be tested.

9. Safety reversal system MUST be tested every month.

Garage door MUST reverse on contact with 1-1/2" 
(3.8 cm) high object (or a 2x4 laid flat) on the floor.

10. ALWAYS KEEP GARAGE DOOR PROPERLY BALANCED

(see page 3). An improperly balanced door may not
reverse when required and could result in SEVERE
INJURY or DEATH.

11. ALL repairs to cables, spring assemblies and other

hardware, ALL of which are under EXTREME tension,
MUST be made by a trained door systems technician.

12. ALWAYS disconnect electric power to garage door opener

BEFORE making any repairs or removing covers.

13.

SAVE THESE INSTRUCTIONS.

Содержание Elite 3800

Страница 1: ...onitor are connected and properly aligned Periodic checks of the opener are required to ensure safe operation The model number label is located behind the hinged door of your opener GARAGE DOOR OPENER...

Страница 2: ...5 Hardware inventory 5 Assembly 6 Attach the collar to the motor unit 6 Attach mounting bracket to the motor unit 6 Installation 7 16 Installation safety instructions 7 Position the opener 7 Attach th...

Страница 3: ...ust have minimum of 2 1 2 6 4 cm between the garage wall and the center of the torsion bar Must have minimum of 3 7 6 cm between the ceiling and the center of torsion bar Must have minimum of 8 20 3 c...

Страница 4: ...opener at 120V 60 Hz to avoid malfunction and damage To prevent possible SERIOUS INJURY or DEATH ALWAYS call a trained door systems technician if garage door binds sticks or is out of balance An unbal...

Страница 5: ...Remote Light with Hardware Bag LOCK LIGHT LCD Motion Detecting Door Control Console Carton Inventory Your garage door opener is packaged in one carton which contains the motor unit and the parts illu...

Страница 6: ...s of torque Figure 2 NOTE For most installations the screws should be facing up for easy access NOTE Do not tighten set screws until indicated 6 Collar Screw Collar Screw Set Screw ASSEMBLY STEP 2 Att...

Страница 7: ...ed garage door might not reverse when required Operator MUST be mounted at a right angle to the torsion bar to avoid premature wear on the collar Motor unit Staple Torsion Bar WARNING CAUTION 14 10x1...

Страница 8: ...nto the motor unit Figure 2 NOTE Lock must be mounted within 10 of the power head NOTICE Overhand Knot Emergency Release Handle Overhand Knot Rope Motor Unit Emergency Release Cable To prevent possibl...

Страница 9: ...it on the opposite side of the cable tension monitor 1 Position the cable tension monitor as shown Figures 1 and 2 The cable tension monitor should be located as close to the drum as possible NOTE Th...

Страница 10: ...r standard installations ONLY Run bell wire up wall and across ceiling to motor unit Use insulated staples to secure wire in several places Do NOT pierce wire with a staple creating a short or open ci...

Страница 11: ...the light lens by hooking one end of the lens over the hinge and pressing up on the other end to latch into place Figure 3 8 Plug in the light to outlet NOTE Light will not operate until the unit is a...

Страница 12: ...nduit or flex cable adapter to the 7 8 hole Reinstall opener to torsion bar Run wires through conduit cut to proper length and strip insulation Attach with wire nuts provided Properly secure wire unde...

Страница 13: ...unit Position the BBU as desired to a structural support ceiling joist or wall stud Attach the BBU to the support using the mounting holes on either side of the BBU Secure the BBU using the 1 1 2 lag...

Страница 14: ...cross the door no more than 6 15 cm above the floor Either can be installed on the left or right of the door as long as the sun never shines directly into the receiving eye lens The mounting brackets...

Страница 15: ...with the lip hugging the back edge of the track as shown in Figure 1 If your door track will not support the bracket securely wall installation is recommended Wall installation Figure 2 and 3 Place th...

Страница 16: ...f wiring connections and alignment are correct The sending eye amber indicator light will glow regardless of alignment or obstruction If the green indicator light in the receiving eye is off dim or fl...

Страница 17: ...the UP position Press and hold the black button until the yellow indicator light starts flashing slowly then release 2 Push and hold the black button until the door reaches the desired UP open positio...

Страница 18: ...o open and close your door The door must travel through a complete cycle UP and DOWN in order for the force to be set properly If the unit cannot open and close your door fully inspect your door to in...

Страница 19: ...r System Press the remote control push button to open the door Place the opener carton in the path of the door Press the remote control push button to close the door The door will not move more than a...

Страница 20: ...ed if possible Pull down on the emergency release handle and lift the door manually To reconnect the door to the opener pull down the emergency release handle straight down a second time The door will...

Страница 21: ...also turn on when someone walks through the open garage door With a Motion Detecting Control Console this feature may be turned off as follows Push and hold the light button for 10 seconds and the inc...

Страница 22: ...will come on for five minutes then shut off This feature works by detecting body heat To disable this feature push the motion sensing button on the side of the door control We recommend that you disa...

Страница 23: ...siding HAVING A PROBLEM TROUBLESHOOTING 1 The opener doesn t operate from either the Control Console or the remote control Does the opener have electric power Plug a lamp into the outlet If it doesn...

Страница 24: ...or Remove any obstruction or align the receiving eye See Installation Step 9 10 The opener strains to operate door The door may be out of balance or the springs may be broken Close the door and use th...

Страница 25: ...hort across red and white terminals with jumper wire If motor unit activates replace door control wires Symptom Sending indicator light glows steadily receiving indicator light is dim or flashing Real...

Страница 26: ...s and hold the button on the hand held remote that you wish to operate your garage door 3 Release the button when the motor unit lights blink It has learned the code If light bulbs are not installed t...

Страница 27: ...he button The opener light will blink three times Release the button 2 Press the temporary 4 digit PIN you have chosen then press Enter The opener light will blink four times 3 To set the number of ho...

Страница 28: ...wall control or keyless entry 3 It has learned the code and the light turns on Reprogramming Light or Additional Light Your garage door opener remote work light has already been programmed at the fac...

Страница 29: ...d 7 41A6104 Cable tension monitor 8 41B6228 Mounting bracket 9 41A5034 Safety sensor kit receiving and sending eyes with 3 9 m 2 conductor bell wire attached KEY PART NO NO DESCRIPTION 10 41B6299 Coll...

Страница 30: ...O DESCRIPTION 1 41DJ001 Logic board complete with plate 2 41A6118 Absolute Encoder System 3 41C168 Transformer KEY PART NO NO DESCRIPTION 4 41A6095 Motor with bracket 5 41B122 Power cord 6 41A6348 Cov...

Страница 31: ...t door of your home Tells you if your garage door is open or closed Monitors up to 4 garage doors by adding additional sensor modules 915LM Garage Door Monitor Sensor Additional accessory sensor for h...

Страница 32: ...is limited warranty will be repaired or replaced at Seller s sole option at no cost to you and returned pre paid Defective parts will be repaired or replaced with new or factory rebuilt parts at Selle...

Отзывы: