background image

of 12

of 12

Performing a  

pre-installation survey 

Before installing the Magnalock, determine and 

assess the mounting location for the following:

• Physical strength of the frame 

 —  should 

be strong enough to meet or exceed the 

holding force of the Magnalock.

• Frame and vicinity

 — should offer protection 

for the wiring to prevent vandalism, and provide 

adequate protection from rain exposure.

• Door

 

inspection

 — inspect for any obstacles 

that may interfere when mounting the strike 

plate and ensure that there is minimum door 

movement when the door is latched.

• Proper

 

mounting

 —The Magnalock comes 

with factory default mounting hardware 

for use with an out-swing door.

Preparing the Magnalock 

Ensure that there is at least 2-1/4" between 

the closed door and the edge of the header.  

If not, a header bracket (sold separately) 

may be required (see 

Diagram 2)

.

Removing the cover 

and mounting bracket 

Using a Phillips screwdriver, REMOVE the two 

(2) screws that secure the cover, as shown in 

Diagram 3a

, and the (3) screws that secure 

the mounting bracket to the top of the 

lock chassis as shown in 

Diagram 3b

SET the cover and screws aside to re-attach later.

SLIDE the bracket to disengage from 

the top of the lock chassis.

Installing the Magnalock 

on a METAL DOOR frame 

NOTE:  Drilling a pilot hole first or using a step 

bit will ensure a snug fit for the blind nuts.

DRILL two (2) 3/8" diameter holes in the 

frame at the bracket mounting hole marks 

(see 

Diagram 7)

. DO NOT oversize.

NOTE 1:  Blind nuts provide a highly secure and tamper-

resistant system for mounting and are provided for this unit.

NOTE 2:  A blind nut installation tool (Securitron BPT-

2, Blind Nut Placement Tool, or similar) can be used 

instead of using a box end wrench and hex wrench.

INSTALL a blind nut into each 3/8" diameter hole 

using the provided tool (see 

Diagram 8)

.

•  Hold the collapsing nut with a 1/2" 

open or box end wrench.

•  Maintain pressure against the mounting 

surface while tightening the cap screw using a 

3/16" hex wrench to collapse the blind nut.

DRILL 1/2" diameter wire access holes as needed, on 

one or both sides of the bracket (see 

Diagram 9)

.

REMOVE the protective tape from the frame.

Temporarily INSTALL the mounting bracket with 

template pins against the closed door using 

a Phillips screwdriver and two (2) 1/4-20 x 1" 

Phillips pan-head screws (see 

Diagram 10

).

Installing the Magnalock 

on a WOOD DOOR frame 

DRILL two (2) 3/16" diameter mounting 

holes by 1-1/4" deep at the bracket-

mounting hole marks (see 

Diagram 7)

DRILL 1/2" diameter wire access holes as needed, on 

one or both sides of the bracket (see 

Diagram 9)

.

REMOVE the protective tape from the frame.

Temporarily INSTALL the mounting bracket with 

the template pins against the closed door using a 

Phillips screwdriver and two (2) #12 x 1-1/2" Type 

A, Phillips pan-head screws (see 

Diagram 10

).

Marking the frame 

PINCH and insert the template pins 

flush into the dovetail slots of the 

mounting bracket (see 

Diagram 4)

.

APPLY MASKING TAPE to the door and 

frame surfaces to protect from any possible 

damage during marking and drilling.

PLACE the mounting bracket against the frame stop 

on the secure side of the door and on the side of the 

door that does not have hinges. Ensure that there 

is a minimum a clearance of 1"  from the frame.

CLOSE the door and adjust the bracket so that 

the template pins rest against the door.

MARK the frame through the two (2) oblong 

(slotted) bracket mounting holes (see 

Diagram 5)

.

MARK the frame for a wire feed-through hole 

at the end closest to where the wire run will be 

accessed and ensure the hole marking is centered 

at least 5/16” from the end and aligned with the 

rear edge of the bracket (see 

Diagram 6)

REMOVE the mounting bracket from the frame.

Diagram 2 Assessing the installation site

Diagram 6 

Marking the wire feed-through hole

Diagram 7 

Drilling the 

bracket mounting holes

Diagram 9 

Drilling the 

wire access holes

Diagram 8 

Installing the blind nuts

Diagram 10 

Installing the bracket

Diagram 3a Removing the cover

Diagram 4 Inserting 

the template pins

Diagram 5 Marking the frame

1-1/8" 

Bracket 

Mounting 

Surface

Anchor Screws

1-11/16" from 

door to center 

of bracket slots

1/4-20 

Blind Nut

A

A

2-1/4" from door to trailing 

edge of bracket

Diagram 3b Removing 

the mounting bracket

1" Min.

5/16" 

3/16" 

Содержание ASSA ABLOY Magnalock DEM680E Series

Страница 1: ...ns Dimensions Height 2 50 64 mm Depth 2 56 65 mm Length 11 50 292 mm Certifications UL 10C Fire Rated 1 Hour CAN ULC S104 Fire Door Conformant UL 294 UL Tested Ratings Endurance 100 000 cycles ANSI BH...

Страница 2: ...needed on one or both sides of the bracket see Diagram 9 4 REMOVE the protective tape from the frame 5 Temporarily INSTALL the mounting bracket with template pins against the closed door using a Phill...

Страница 3: ...IGHTEN the screw into the sex bolt using the 3 16 hex wrench While tightening gently tap the head of the sex bolt using a rubber mallet until the head sits flush with the door NOTE To provide maximum...

Страница 4: ...dooropens Normally open 2 3 Normally closed NC Normallyclosedcircuit openswhendooropens JP3 EXT INIT 1 2 Disabled Whenenabled allowsunitto beinitiatedfromanexternal source J1 Terminal4 Disabled 2 3 En...

Страница 5: ...PERFORM amanualcalibrationimmediately followinginstallation ifnecessary 1 ENSURE that the door is closed 2 APPLY power to the Magnalock 3 PRESS AND RELEASE the calibration button see Diagram 34 4 VER...

Страница 6: ...ld turn red and the door should freely open see Diagram 39 After testing close the door and perform a reset After reset the strobe should turn off and the LED should change from red to green VERIFICAT...

Страница 7: ...E Each DEM680E comes with an NFPA exit delay door label as required by fire code 1 FOLLOW the included application instructions to apply the lettering to a door Restoring factory defaultsettings 1 DIS...

Отзывы: