1. Position the wall plate
10
on the wall at your desired height. Level the wall plate and mark the four hole locations.
2. Drill four pilot holes using a 3/8 in. (10 mm) diameter masonry drill bit.
IMPORTANT:
Pilot holes must be drilled to a depth of 3 in. (75 mm). Never drill into the mortar between blocks.
2
1
10
3/8 in.
(10 mm)
3 in. (75 mm)
STEP 2B
Attach Wall Plate
Solid Concrete or Concrete Block Option
CAUTION:
Avoid potential personal injury or property damage!
•
Mount the wall plate
10
directly onto the concrete surface
•
Minimum solid concrete thickness: 8 in. (203 mm)
•
Minimum concrete block size: 8 x 8 x 16 in. (203 x 203 x 406 mm)
•
Minimum horizontal space between fasteners: 16 in. (406 mm)